8
9
English
TROUBLE SHOOTING
MALFUNCTION
CAUSE
RECTIFICATION
Top blade does not move Clipper-head is not well engaged
Engage the clipper-head correctly when the
motor is running
Drive carrier is defective
Replace drive carrier (*)
Clipper cuts badly or not
at all
Clipper blade is blunt
Have top and bottom blades re-sharpened by
Oster
TM
authorized service center
Clipper blade have not been
correctly grounded
Clipper blades are not oiled
Oil clipper blades every 15 minutes
Hairs jammed between top and
bottom blades
Take off clipper-head, push the top blade half
away from the clipper head, take away hairs
between top and bottom blade
Clipper-head has too little clipping
pressure
Have clipper-head inspected (*)
Motor is not running
Battery is not charged
Charge battery
Contacts dirty
Switch clipper «OFF» (O) and clean the
contacts
Faulty battery
Replace battery (*)
Smell of burning from the motor
housing. Motor burned out
Have motor and / or electronics replaced (*)
Motor and / or electronics faulty
Have motor and / or electronics replaced (*)
Clipper-head blocked
Clean and oil clipper-head
Motor runs very slowly
Clipper blades were not oiled
sufficiently
Oil clipper blades
Running time of a fully
charged battery is too
short and / or blades are
getting hot
Clipper blades were not oiled
sufficiently
Oil clipper blades
Battery is not fully charged, or
faulty battery is being used
Only use intact, fully charged original batteries
When battery is
unloaded the light does
not change from green
to red
Contacts dirty
Clean contacts
Faulty battery
Replace battery (*)
Contacts of the charging station are
deformed
Have the charging station repaired (*)
English
BLADES
To clean the blades, fill a flat dish with Oster™ Blade Wash
®
cleaning solution and immerse only the blade teeth.
DO NOT IMMERSE THE APPLIANCE.
Turn «ON» (|) the appliance with the blades facing down. Do not hold the
appliance upright when cleaning blades with the appliance plugged in. Listen for a change in the hum of the
motor. As the build-up is removed, the clean blade runs faster and at a higher pitch. When the pitch stabilizes
(between 30 to 60 seconds), turn «OFF» the appliance and unplug. Remove from the cleaning solution and, while
holding the appliance with the blade end facing down, wipe the blades dry with a clean, dry cloth. Re-oil blades.
Always unplug the appliance when carrying out other cleaning and do not immerse the appliance body, charging
stand, adapter, power cord or plug in water or any other liquid.
CHARGING STATION
1. Disconnect the charging station from the power supply.
2. If necessary, remove hairs from both charging cavities.
3. If dirty, clean the contacts with a dry cloth.
CONTACTS
If required, clean the contacts of the batteries and the clipper with a dry cloth.
Any maintenance beyond the cleaning and lubricating instructions in this manual should be performed by an
Oster™ Authorized Service Center.
The tasks described here for troubleshooting can be done mostly by the operator.
Some tasks only may be done by specially trained personnel or by an Oster
TM
authorized service center. These
tasks are marked with (*).
CLEANING
When using or cleaning this appliance, do not use any aerosol sprays or blade washes,
especially those containing methylene chloride, dimethyl benzyl ammonium chloride, or 1-1-1
trichloroethylene. Damage caused by these chemicals will void your warranty. You may use
Oster
TM
approved blade washes, lubricants and disinfectant sprays that do not harm the product.
WARNING
076076-810_076076-910_078005-210_21ESFM2.indd 8-9
076076-810_076076-910_078005-210_21ESFM2.indd 8-9
5/27/21 10:35
5/27/21 10:35