Operating Instructions Sauna exclusiv 9kW    Page: 6

shows a short-circuit.

 

 

 

Checking the temperature sensor:

 

 

  Disconnect both cable conductors of the

white line from the clamps 7 and 8
located at the  the control device.

  Measure the temperature sensor with a

resistance meter.

At room temperature an intact temperature
sensor shows an electric restistance of
approx. 68kOhm (see accompanying
coordinate).

5.)

Should the set temperature not be reached with a properly working temperature
control:
5.1.

The temperature sensing system has to be installed according to fitting
instructions. Should the sensor have been placed in the warm air flow above
the heater, it needs to be moved sideways as far as the rising warm air cannot
cause an early switching off of the heater.

5.2.

Should the sauna heater be switched off with
soundly installed sensing system, this problem is
then to be solved by adjusting the temperature
range. For this a trimming potentiometer has
been placed on the circuit board (see sketch).

Sensor alignment

We wish you a lot of pleasure and relaxation in your sauna.

Subject to alteration!  

 