Operating Instructions Sauna exclusiv 9kW    Page: 3

Operational controls on the control panel:

LCD-display

ON/OFF button

Counter Timer

Ventilator button

Cabin lighting button

Temperature selection
Adjusting buttons
Setting time

button

Setting switch timer

LCD-Display

16:10

If the control is switched off, then only the current time is displayed.

Power failure

16:10

If the power supply has been interrupted, this is indicated on the
display. The display will disappear on pressing any button.

22:35h

Start in:

16:10

The counter timer has been activated. Referring to the current time
the remaining time up to finally switching on the equipment is
displayed.

2:35h

Sauna time

16:45

82,3°C

The sauna control is in operation. Time, temperature in the cabin and
the remaining operational time are displayed.

Sensor defect

18:32

The temperature sensor in the sauna cabin is defect or the line to the
temperature sensor has been interrupted or short-circuited. After the
error has been handled this message may be deleted by pressing any
button.

Temp. fuse

12:55

144,8°C

The temperature in the sauna cabin has exceeded 139°C. This could
have triggered the temperature safety fuse in the sensor casing. After
the cabin has been cooled down this message may be deleted by
pressing any button.

Unit overheated

21:03

98,3°C

The temperature in the power component casing is too high. After
cooling down the control, this message may be deleted by pressing
any button.

ON/OFF button

By using the   button the sauna may manually be switched on and –off.
Attention! By this the control is not discharged with tension! If the sauna is
switched on this button is on.