Operating instructions    PC-30-Vario filter control unit    Page: 4 

absorber  temperature  must  not  exceed 
80°C at the temperature sensor. 

Connecting  terminals  are  provided  for  an 
NR-12-TRS-2 electronic water level control 
unit  (part  no.  3030075020)  for  convenient 
automatic  control  of  the  water  level  in  the 
swimming pool. This also protects the filter 
pump  from  any  damage  which  might  arise 
from  running  the  filter  installation  without 
water. 

The INFO button on the front panel can be 
used  to  change  the  user  language  and  to 
retrieve various operating parameters.  

Spare 

terminals 

are 

available 

for 

connecting  additional  devices  such  as 
chemical  dosing  equipment.  Terminals 
24+25 are floating contacts for custom use. 
The  relay  contact  between  terminals  24 
and 25 is closed during the filter operating 
times and open outside the filter operating 
times. This contact is rated for a maximum 
voltage of 230V and a maximum current of 
3A. 

The  connecting  terminals  for  the  winding 
protection 

switch 

are 

designed 

for 

connecting  a  thermal  winding  protection 
switch  built  into  the  filter-pump  motor 
winding.  If  this  switch  opens,  e.g.  as  a 
result of the motor winding getting too hot, 
the filter pump is switched off automatically 
along 

with 

the 

heater 

and 

dosing 

equipment.  Once  the  winding  protection 
switch  closes  after  the  motor  winding  has 
cooled  down,  the  units  are  automatically 
switched  back  on.  There  is  no  need  for  a 
manual reset. The connecting terminals for 
the winding protection switch carry 230V. 

Indicator  lights  in  the  front  panel  show 
when  the  filterpump  and  heater  are 
running,  allowing  easy  checking  of  the 
status. 

ECO mode can be started automatically on 
closure  of  the  swimming  pool  cover  (limit-
switch terminals 28 + 29). 

 

 

Installation

 

The  swimming  pool  must  be  designed  to 
prevent  consequential  damage  resulting 
from  a  potential  technical  fault,  power 
failure or faulty controller. 

 

Electrical connection 

The  control  unit  must  be  mounted  such 
that  it  is  protected  from  moisture  in 
accordance  with  its  degree  of  protection. 
The  power  supply  for  the  unit  must  be 
provided  via  an  all-pole  disconnection 
switch  with  minimum  contact  gap  of  3mm 
and  via  a  residual-current  circuit  breaker 
with a fault current   IFN of 

 30mA. When 

using variable-frequency drives and speed-
controlled  pumps,  the  residual-current 
circuit breakers stipulated for these devices 
must  be used and the relevant  regulations 
observed. 

 

Always  disconnect  the  unit  from  the 
power  supply  before  opening  the  case. 
All  electrical  wiring  and  calibration  and 
servicing  work  must  be  performed 
solely  by  an  approved  electrician.  The 
attached  wiring  diagrams  and  all 
applicable  safety  regulations  must  be 
observed. 

The  switching  outputs  of  the  PC-30-Vario 
are  not  intended  as  a  voltage  supply  for 
variable  frequency  drives.  Please  refer  to 
the  relevant  wiring  diagrams  in  these 
operating instructions. 

Low-voltage lines   

Low-voltage  lines  must  not  be  laid  along 
with three-phase or AC power cables in the 
same  cable  conduit.  In  general,  always 
avoid  routing  low-voltage  lines  close  to 
three-phase or AC power cables. 

Connecting the filter pump 

Note  that  it  is  permitted  to  connect  only 
one  pump.  Connections  must  be  made  in 
accordance  with  the  following  wiring 
diagrams. 

Содержание Poolcontrol-30-Vario

Страница 1: ...hing capacity Pump max 8A 1 0 kW AC3 Heater max 3A 0 4 kW AC3 Dosing system max 3A 0 4 kW AC3 Degree of protection IP 40 Level sensors Safety Extra Low Voltage SELV Ambient temperature 0 40 C Air humi...

Страница 2: ...g mode 10 Controls on the front panel 11 LCD display 11 Operating mode selection 11 Pump indicator light 12 Heater indicator light 12 Heater switch 12 Solar heater indicator light 12 Solar heater swit...

Страница 3: ...ng slide valves and launched either manually or at a specific time or pressure While the filter pump is running the swimming pool heater is controlled by the electronic temperature controller During b...

Страница 4: ...in the front panel show when the filterpump and heater are running allowing easy checking of the status ECO mode can be started automatically on closure of the swimming pool cover limit switch termina...

Страница 5: ...be connected directly to the PC 30 Vario unit Connect the speed controller to terminals 15 20 There must be a link inserted between the two WSK terminals winding protection switch Always refer to the...

Страница 6: ...itching behaviour for the Stop function must be set to Stop when contact open oP Connecting a Speck Badu 90 ECO Motion pump A Speck Badu 90 ECO Motion pump can be connected directly to the PC 30 Vario...

Страница 7: ...be provided for the pump The power supply cannot be provided by the PC 30 Vario There must be a link inserted between the two WSK terminals winding protection switch Always refer to the operating ins...

Страница 8: ...t a NR 12 TRS 2 unit If the PC 30 Vario is intended to be operated without an NR 12 TRS 2 unit terminals 13 and 14 must be connected together with a link Disconnect the connecting cable before doing s...

Страница 9: ...31 sensor Solar 32 33 PC 30 Vario thermowell Connect the swimming pool temperature sensor to terminals 30 and 31 The temperature sensor is supplied as standard with a cable length of 1 5m If required...

Страница 10: ...setting the filter system is activated In this case the temperature controller regulates the heater to a target temperature of 3 C Fuses The electronic controller is protected by a 0 5A microfuse loc...

Страница 11: ...d Clear washing The filter pump is on because rinsing is in progress using the connected sliding valve Heater is disabled pump locked The filter pump is off because the winding protection switch has t...

Страница 12: ...e colour of the light indicates the heater operating mode off the heater is off green the heater is running red the heater is disabled You can use the button to switch the heater on or off Solar heate...

Страница 13: ...ss the button the day of the week flashes 6 You can now use the and buttons to set the day of the week To save the set time press the button again If no button is pressed during an interval of more th...

Страница 14: ...been programmed yet 2 After pressing either button or or if a switching time has already been programmed the display shows 0 00 0 00 1 and the minutes in the top time display flash switch on time Note...

Страница 15: ...you can press the button to adopt the current time pressing both and buttons at once deletes the cycle start time Pressing and holding the button for longer than 5 seconds will launch a backwash rinse...

Страница 16: ...ic text e g Filtersystem off Temp reached Water 23 0 Solar 38 4 Filter system operating mode Heater operating mode measured water temperature measured collector temperature Use the and buttons on the...

Страница 17: ...the set target temperature Solar heater on The solar heater is on because the water temperature is below the set target temperature and the collector is warmer than the swimming pool water Frost risk...

Страница 18: ...the display shows Solar dif off difference temp between water and collector 0 5 You can now use the and buttons on the terminal to change the temperature difference The lowest value you can set is 0...

Страница 19: ...particular heating system make sure it is displayed in the top line 1 After pressing the button on the terminal the filter system is switched off and the display shows Min heating s Min switching time...

Страница 20: ...value is saved automatically The filter pump run on is factory set to off run on time 0 Priority of temperature controller over timer Display text Heat priori This line displays whether the temperatu...

Страница 21: ...n now use the button on the terminal to enable priority mode and the button to disable it again 3 If you press the button again the standard diagnostics display reappears and the filter system resumes...

Страница 22: ...line of the Service Terminal 1 After pressing the button on the terminal the filter system is switched off and the display shows water frost Water temperature with freze protection 3 0 2 You can now...

Страница 23: ...play text In backwash This line displays how often a backwash operation using sliding valves has been launched Backwash counter external Display text Ex backwash This line displays how often a backwas...

Страница 24: ...fter pressing the button on the terminal the filter system is switched off and the display shows Filter pump OFF Pump can be operated manually 2 You can now use the and buttons on the terminal to swit...

Страница 25: ...tor ON Pump OFF Dosing equip OFF Filter pump OFF manual operating 2 You can now use the button on the terminal to switch on the dosing system and the button to switch it off again The filter pump is a...

Страница 26: ...correctly together If one of the sensors is replaced or a sensor lead is lengthened the system may need to be recalibrated using the Info button on the control unit Since the solar temperature control...

Отзывы: