Operating instructions PC-30-Vario filter control unit Page: 5
Connecting a 230V AC filter pump without speed control
The factory-inserted link between the two WPS terminals
must be removed when connecting a pump fitted with a
winding protection switch. If the pump does not have a
winding protection switch, the link must remain screwed in
place. These terminals are live and carry a mains voltage!
Connecting a Speck ECO-Touch pump
A Speck ECO-Touch pump can be connected directly to
the PC-30-Vario unit. Connect the speed controller to
terminals 15-20.
There must be a link inserted between the two WSK
terminals (winding protection switch).
Always refer to the operating instructions for the pump.
Connecting a Speck ECO-Touch-Pro pump
A Speck ECO-Touch-Pro pump can be connected
directly to the PC-30-Vario unit. Connect the speed
controller to terminals 15-23.
A separate mains power supply must be provided for the
pump. The power supply cannot be provided by the PC-
30-Vario.
There must be a link inserted between the two WSK
terminals (winding protection switch).
Always refer to the operating instructions for the pump.