Operating instructions PC-30-Vario filter control unit Page: 12
Automatic The filter system is switched on and off by the timer.
Eco
When the timer is on, the filter pump runs at low speed.
Manual
The filter system is running continuously.
Pump indicator light
These indicator lights indicate which mode the filter pump is running in.
Pump is disabled. It may have been switched off by the winding protection switch,
by the water level controller or by the EUROTRONIK-10 controller.
All lights OFF:
the filter pump is off.
BOTTOM light ON:
the filter pump is running in ECO mode.
BOTTOM
and
CENTRE light ON:
the filter pump is running at normal speed.
All 3 lights ON:
the pump is running at maximum speed.
Heater indicator light
Heater switch
This indicator light shows the heater operating mode. The colour of the light
indicates the heater operating mode:
off:
the heater is off.
green:
the heater is running.
red:
the heater is disabled.
You can use the button to switch the heater on or off.
Solar heater indicator light
Solar heater switch
If a solar sensor is connected to the controller, this indicator light shows the
current operating state of the solar heater.
off:
the solar heater is off (temperature controller).
green:
the solar heater is running.
red:
the solar heater is off (switch).
You can use the button to switch the solar heater on or off.
Backwash using sliding valve
This indicator light shows whether a backwash operation using sliding valves is
currently in progress.
Temperature selection
Use the button to select the water temperature for the swimming pool:
1. Press the button
the display shows
24.5
water
:
°C
2. You can now use the
and
buttons to set the temperature you require in a
range of 0°C to 40°C.
3.
To save the required temperature, press the
button again. If no button is