Label
Description
Mode
Indicates if 802.1X and MAC-based authentication is globally enabled or
disabled on the switch. If globally disabled, all ports are allowed to
forward frames.
Reauthenticati
on Enabled
If checked, clients are reauthenticated after the interval specified by the
Reauthentication Period. Reauthentication for 802.1X-enabled ports can
be used to detect if a new device is plugged into a switch port.
For MAC-based ports, reauthentication is only useful if the RADIUS
server configuration has changed. It does not involve communication
between the switch and the client, and therefore does not imply that a
client is still present on a port (see Age Period below).
Reauthenticati
on Period
Determines the period, in seconds, after which a connected client must
be re-authenticated. This is only active if the
Reauthentication
Enabled
checkbox is checked. Valid range of the value is 1 to 3600
seconds.
EAPOL
Timeout
Determines the time for retransmission of Request Identity EAPOL
frames.
Valid range of the value is 1 to 65535 seconds. This has no effect for
MAC-based ports.
Содержание IGS-9168GP series
Страница 61: ...IGS 9168GP User s Manual ORing Industrial Networking Corp 60...
Страница 62: ...IGS 9168GP User s Manual ORing Industrial Networking Corp 61...
Страница 146: ...IGS 9168GP User s Manual ORing Industrial Networking Corp 145 Step 3 Select a COM port in the drop down list...
Страница 149: ...IGS 9168GP User s Manual ORing Industrial Networking Corp 148 Commander Groups...
Страница 164: ...IGS 9168GP User s Manual ORing Industrial Networking Corp 163 Modbus Modbus Status Mode enable disable...