5 Connection
-
23
-
RUN/BRAKE input
RUN is selected when the input is on (L level), and motor starts running. BRAKE is
selected when the input is off (H level), and motor stops instantaneously.
INSTANTANEOUS STOP
RUN
OFF "H"
ON "L"
START/STOP input
RUN/BRAKE input
CW/CCW input
Motor operating pattern
OFF "H"
ON "L"
OFF "H"
ON "L"
CW
CCW
RUN
STOP
START
STOP
RUN
BRAKE
RUN
CCW
CW
∗
∗
∗
∗
∗
10 ms minimum
CW/CCW input
CW is selected when the input is on (L level). CCW is selected when the input is off
(H level). The drive direction is the same as that of the motor output shaft when
viewed from the motor output side.
Note
Depending on the gearhead ratio, the drive direction of the gear output shaft
may be opposite of that of the motor. Refer to catalogue.
INT.VR/EXT input
INT.VR is selected when the input is on (L level), and the setting speed of internal
potentiometer is enabled. EXT is selected when the input is off (H level), and the
setting speed of external potentiometer or external DC voltage is enabled. Switching
this signal allows combined use of the external potentiometer or external DC voltage
or two-speed switching operation. When the internal potentiometer is not used, there
is no necessity even if there is no connection.
INSTANTANEOUS STOP
RUN
OFF "H"
ON "L"
START/ STOP input
RUN/BRAKE input
CW/CCW input
Motor operating pattern
OFF "H"
ON "L"
OFF "H"
ON "L"
CW
CCW
RUN
INT.VR /EXT input
OFF "H"
ON "L"
INSTANTANEOUS
STOP
RUN
INT.VR
EXT
INT.VR
EXT
START
RUN
BRAKE
RUN
CCW
CW
BRAKE
INT.VR
INT.VR
EXT
∗
∗
∗
∗
∗
∗
10 ms minimum