Maintenance and servicing
13
7
7
Maintenance and servicing
Regular checks of the pellet heating system are a prerequisite for reliable, efficient and environment-friendly
operation.
7.1 Maintenance
Maintenance, boiler cleaning and cleaning of flue gas connection are necessary at least once a year. Pellets
which produces tendentially more slagging (ash melting point <1300 ° C) and pellets with higher bulk density
(> 650kg) leads to additional cleaning of the burner plate at regular intervals.
7.2 Emptying the ash pan
R
Riissk
k o
off b
bu
urrn
nss
Use gloves.
Do not touch the boiler vessel.
R
Riissk
k o
off ffiirre
e
Do not empty ash into a flammable container.
Do not empty ash onto flammable floors or materials.
Do not dispose of ash until it has completely cooled
down.
Note:
Check the level of the ash box and empty it at regularl intervals (at least every 2 weeks).
Operating Manual Easypell® 16 — 32kW
Содержание Easypel
Страница 1: ...Operating Manual Easypell 16 32kW ENGLISH...
Страница 14: ...14 Emptying the ash pan 200013_EN 1 2...
Страница 16: ...16 Cleaning the boiler every year Procedure for cleaning the boiler 200013_EN 1 2...
Страница 18: ...18 Cleaning the boiler every year Cleaning the Induced draft blower 200013_EN 1 2...
Страница 38: ......
Страница 39: ......
Страница 40: ......