background image

32

Status display

9

9..2

2..2

2 S

Stta

attu

us

s d

diis

sp

plla

ay

y

The current status is displayed.
No settings can be entered.

This display is for information only.

Pressing the button

repeatedly returns you to the start screen.

Status display symbols:

Display

Description

Pump output active.

Minimum boiler temperature (pump release) has not been reached.

Time program active.

Burner demand via burner contact / thermostat.

Warning

200013_EN 1.2

Содержание Easypel

Страница 1: ...Operating Manual Easypell 16 32kW ENGLISH...

Страница 2: ...N 1 2 Version valid from 09 2015 Approved Wohlinger Christian Author Eco Engineering 2050 GmbH A 4132 Lembach M hlgasse 9 Tel 43 0 72 86 74 50 Fax 43 0 72 86 74 50 10 E Mail office easypell com by Eco...

Страница 3: ...e el ll l 1 11 1 7 7 M Ma ai in nt te en na an nc ce e a an nd d s se er rv vi ic ci in ng g 1 13 3 7 1 Maintenance 13 7 2 Emptying the ash pan 13 7 3 Cleaning the boiler every year 15 8 8 O Op pe er...

Страница 4: ...read this manual right through and take note of the safety warnings Keep all documentation supplied with this unit in a safe place for future reference Please pass on the documentation to the new user...

Страница 5: ...ld lead to death or life threatening injury Warning indicates a situation that could lead life threatening or serious injury Caution indicates a situation that could lead to injury Note indicates a si...

Страница 6: ...ed with suffi cient combustion air The openings in the combustion air inlet must never be partially or completely closed Ventilation systems central vacuum cleaning systems extractor fans air conditio...

Страница 7: ...op pe er rt ty y Heat the pellet heating system using pellets that comply with EN 14961 2 class A1 and A2 only D Da am ma ag ge e t to o p pr ro op pe er rt ty y Do not use the heating system if it or...

Страница 8: ...ntaining chlorine nitrobenzene or halogen in the room where the heating system is installed if combustion air is drawn directly from the room Do not hang out washing in the central heating room Preven...

Страница 9: ...e of the boiler Safety temperature sensor The pellet boiler is equipped with a safety temperature sensor This is located on the pel let boiler If the boiler temperature exceeds 95 C then the heating s...

Страница 10: ...et ts s o of f n na at tu ur ra al l w wo oo od d t th ha at t c co om mp pl ly y w wi it th h s st ta an nd da ar rd d E EN N 1 14 49 96 61 1 2 2 c cl la as ss s A A1 1 w wi it th h a a d di ia am me...

Страница 11: ...d 32kW Note Refer to the data plate for the power rating of your Easypell The data plate is located on the rear side of the boiler Here you find the type designation manufacturer s serial number and y...

Страница 12: ...late 7 Suction fan 2 Flame tube 8 Anti blowback system 3 Heat exchanger 9 Burner auger 4 Boiler water 10 Electronic ignition 5 Boiler insulation 11 Combustion chamber sensor 6 Combustion chamber cover...

Страница 13: ...elting point 1300 C and pellets with higher bulk density 650kg leads to additional cleaning of the burner plate at regular intervals 7 2 Emptying the ash pan R Ri is sk k o of f b bu ur rn ns s Use gl...

Страница 14: ...14 Emptying the ash pan 200013_EN 1 2...

Страница 15: ...s Do not clean the boiler until it has been allowed to cool down Switch off the heating system at least 6 hours before opening the boiler Switch off the main switch before starting any mainte nance wo...

Страница 16: ...16 Cleaning the boiler every year Procedure for cleaning the boiler 200013_EN 1 2...

Страница 17: ...p pe er rf fo or rm ma an nc ce e a an nd d d da am ma ag ge e t to o p pe el l l le et t b bo oi il le er r d du ue e t to o b bl lo oc ck ka ag ge es s i in n t th he e a ai ir r i in nl le et t Cle...

Страница 18: ...18 Cleaning the boiler every year Cleaning the Induced draft blower 200013_EN 1 2...

Страница 19: ...dren away from the central heating room and storage room F Fi ir re e r ri is sk k Keep the ash removal door closed while the boiler is in operation 8 1 Description of the control panel The control pa...

Страница 20: ...played the set value can be changed When this function is selected the value can be changed by pressing the arrow keys When this function is selected you leave the menu without saving the changed valu...

Страница 21: ...ile the fire protection device is being opened approx 2 minutes After the fire protection device has been opened the ignition process starts and the symbol for ignition is displayed On completion of t...

Страница 22: ...emperature Note This function is only available if a DHW sensor is connected to the boiler controller Please also refer to the installation manual chapter 13 Controller for heating and hot water The c...

Страница 23: ...he value can be raised or lowered by pressing the keys button save value The stored value is displayed button 9 9 1 1 1 1 S Se et tt ti in ng g t th he e t ti im me e p pr ro og gr ra am m f fo or r D...

Страница 24: ...tton Cursor at the hour button The value can be set by pressing the keys button save value Cursor jumps to the minute Other values minutes and hours are set as described above Note The set heating per...

Страница 25: ...time program for DHW heating 25 button Cursor at the symbol button button Activate the set heating periods The symbol shows that the heating periods have been activated and saved Operating Manual Easy...

Страница 26: ...26 Setting the time button 9 9 1 1 2 2 S Se et tt ti in ng g t th he e t ti im me e The current time is displayed Note The time is set in the same way as the heating periods button 200013_EN 1 2...

Страница 27: ...ion only Pressing the button repeatedly returns you to the start screen Status display symbols Display Description DHW priority active heating circuit demand is subordinate Pump output active Minimum...

Страница 28: ...l chapter 13 Controller for heating and hot water If heating periods are programmed the boiler runs at the set times During these periods burner requests from the external controller terminal 7 8 are...

Страница 29: ...The value can be set by pressing the keys button save value Cursor jumps to the minute Other values minutes and hours are set as described above Note The set heating period still needs to be activate...

Страница 30: ...30 Setting the boiler heating period button Cursor at the symbol button button Activate the set heating periods The symbol shows that the heating periods have been activated and saved 200013_EN 1 2...

Страница 31: ...the time 31 button 9 9 2 2 1 1 S Se et tt ti in ng g t th he e t ti im me e The current time is displayed Note The time is set in the same way as the heating periods button Operating Manual Easypell...

Страница 32: ...be entered This display is for information only Pressing the button repeatedly returns you to the start screen Status display symbols Display Description Pump output active Minimum boiler temperature...

Страница 33: ...e The system restarts automatically when the cause has been eliminated Overview of malfunction alarm texts Display Error code 0 Description Boiler sensor fracture measuring circuit from boiler sensor...

Страница 34: ...ure too low sensor temperature below measuring range 10 C sensor polarity incorrect exchange and connections Display Error code 4 Description Negative draft input open measuring circuit from negative...

Страница 35: ...to cool and reset alarm Display Error code 8 9 Description Flue gas minimum temperature not reached during ignition phase Cause and Remedy no pellets available fill up with pellets ignition electrode...

Страница 36: ...connectors Display Error code 14 Description Container cover open Cause and Remedy Cover open close cover End switch defect replace end switch Display Error code 15 Description DHW sensor fracture me...

Страница 37: ...e original Eco Engineering spare parts only Not using original Eco Engineering spare parts will cause the warranty to become void 10 5 Checking the central heating room and storage room Checking the p...

Страница 38: ......

Страница 39: ......

Страница 40: ......

Отзывы: