User manual
FLEXI 50
19
8.3
Ventilator control with the buttons on the indoor unit
The speed selection sequence is as follows: I-II-Ill-Standby. All the units integrated in a single
network operate according to the speed settings of the Master unit.
•
I: permanent indicator glowing indicates operation of the unit at Speed I. Indicator
blinking indicates activation of the Night mode timer.
•
I and II: permanent glowing of these indicators indicates operation of the unit at Speed
II.
•
I, II and Ill: permanent glowing of these indicators indicates operation of the ventilation
unit at Speed Ill. Synchronous blinking of the indicators I, II and Ill indicates activation of
the timer in the
Party mode
or the turn-off delay timer in the
Boost mode
in case of
actuation of the connected external sensors or the integrated humidity sensor.
•
Alternate blinking of the indicators I, II and Ill indicates that the ventilator runs at the
speed set with the mobile application using the slider selector for manual speed setting
or that the
Weekly Schedule mode is activated.
Regeneration mode
The rotation direction of both fans changes to opposite every 70 seconds. Heat
recovery is performed in this mode. To enable reverse phase operation of the
ventilators, change the position of the DIP switch No. 3.
Ventilation mode
The ventilator operates in the supply or extraction mode at a set speed. The fan rotation direction
depends on the position of the DIP switch No. 3.
No glowing of the indicators "
Regeneration
" and "
Ventilation
" indicates forced operation of the ventilation
unit in the air supply mode. This mode may be activated only via the
mobile application
.
8.4
Description of the indicators on the indoor unit
FILTER
90 days after installation of the cartridge the filter replacement indicator starts glowing. In this
case, clean or replace the filters (see section Maintenance).
After replacement or cleaning of the filters reset the timer using the mobile application or by
pressing and holding the
button on the Master ventilator indoor unit for 5 seconds
until a signal sounds.
ALARM
Alarm indicator.
In case of failure, the Alarm indicator on the indoor unit glows or blinks. Reasons of Alarm
blinking:
•
Battery charge is below the low level.
•
No connection between the Master unit and the router.
•
Alarm shutdown of the ventilator.
If several interconnected ventilators are running in the same network, in case of alarm
shutdown of the ventilator, all of the ventilators of this network also stop. The alarm indicator
blinks on the defective ventilator and glows on the other connected ventilators.
In case of communication loss of the
Master
unit with the router for longer than 20 seconds,
the
Master
unit
switches to
Standby
mode
(Alarm indicator blinking) and the
Slave
units will
signal that there is no communication with the
Master unit
(see the description of the Master
indicator). After resuming communication, the Slave units are automatically synchronised with
the
Master unit
.
MASTER
UNIT
Permanent glowing of the indicator shows the leading unit in the network (Master unit).
Indicator blinking indicates the driven unit (Slave unit) and no connection to the Master unit.
No glowing of the indicator means that this ventilator is a Slave unit and it is connected to a
Master unit.