1 5
Oracle Talari E100 Hardware Guide
Bypass Configuration using the LCD
The bypass configurable option on the LCD will appear once the unit is initially powered
on and will last for 30 seconds.
If the user selects “Yes” on the LCD, this will set the device to Inline
mode (interfaces in Fail-to-Wire), allowing traffic to pass.
If the user selects “No” on the LCD, this will set the device to Router
mode (interfaces in Fail-to-Block).
If there is no response after 30 seconds, the unit will select the default setting of
Router mode (interfaces in Fail-to-Block).
NOTE:
The user’s response is retained until either a configuration is loaded containing
a different Ethernet Interface configuration than the one the user initially selected, or the
unit is set to factory defaults.
Is your E100 installation / site bring up:
Leveraging the Talari Cloud for APN Easy 1
st
Install? If so, please
CONTINUE to
Page 11 or 12
(based upon desired topology).
Using the legacy method for deploying the E100 Appliance? If so, please
SKIP to
Page 13.