background image

 

 

3 1

 

 

The USB burn process on a USB3 device can take 15 minutes. It may take longer if the 
device or port is USB2. After the process is complete, you can remove the USB. It is 
ready for use.  

Содержание Talari E100

Страница 1: ...Oracle Talari E100 Hardware Guide Publication Date August 2020...

Страница 2: ...ghts are granted to the U S Government This software or hardware is developed for general use in a variety of information management applications It is not developed or intended for use in any inheren...

Страница 3: ...d Inspection 11 Rack Mounting 11 Safety Recommendations 11 LAN WAN Connections 12 Important Note About Cabling and Bypass Mode 12 Powering Up the Appliance 12 Network Deployment Options 13 E50 as a Ro...

Страница 4: ...t My Oracle Support https support oracle com is your initial point of contact for all product support and training needs A representative at Customer Access Support CAS can assist you with My Oracle S...

Страница 5: ...that results in loss of all transaction processing capability Significant reduction in system capacity or traffic handling capability Loss of the system s ability to perform automatic system reconfigu...

Страница 6: ...ocation right click the PDF link select Save target as or similar command based on your browser and save to a local folder Reference Documents The following documents are available Talari APN Glossary...

Страница 7: ...uire a standard 19 inch 480mm two post rack for mounting Software The APNA Web Console is supported in latest versions of the following web browsers Microsoft IE9 IE11 Mozilla Firefox Google Chrome Su...

Страница 8: ...reliability at consumer prices Talari APN Appliances APNAs are seamlessly added to existing networks to deliver more bandwidth reduced WAN operating expenses and greater reliability than any existing...

Страница 9: ...at the system is powered on If it is off it indicates that the system is powered off Status If the LED is green it indicates that the system s operational state is normal If it is red it indicates tha...

Страница 10: ...r with Port 1 as Fail To Wire 3 User defined Fail To Block by Default configurable as a Bypass pair with Port 4 as Fail To Wire 4 User defined Fail To Block by Default configurable as a Bypass pair wi...

Страница 11: ...ernet Off Link 10 Status Mbps LED Green 100 Mbps Amber 1000 Mbps Fans Power Reset Oracle Talari E100 Hardware Guide NIC Indicator Codes Ethernet ports on the front panel have indicator lights for info...

Страница 12: ...ount recessed flanges System LEDs Front Panel Power Status HDD Link LEDS Front Panel Link Activity Link Speed Operating Temperature 32 F to 104 F 0 to 40 C Storage Temperature 4 F to 158 F 20 C to 70...

Страница 13: ...before pulling a component out of the rack Do not move racks by yourself at least two people are needed to move a rack and to safely stage equipment Cables should be easily identifiable LAN WAN Conne...

Страница 14: ...here should be no need for crossover cables Talari recommends testing and verifying this capability with the APNA powered off for proper operation For assistance please contact your Talari representat...

Страница 15: ...es in Fail to Block If there is no response after 30 seconds the unit will select the default setting of Router mode interfaces in Fail to Block NOTE The user s response is retained until either a con...

Страница 16: ...Connect the green Enterprise LAN Port 1 cable to the E100 port 1 with the other end of the cable connected to a LAN switch 2 Connect the orange WAN 1 Port 2 cable to the E100 port 2 with the other end...

Страница 17: ...mpted with Ports in Bypass Yes No on the LCD select Yes to proceed with the appliance in Inline mode with interfaces in Fail to Wire 15 The E100 will begin communication with the Talari Registration S...

Страница 18: ...atisfied with the settings select Change Settings Be sure to change the network interface settings on your PC back to the original settings After the network administrator has created the Client packa...

Страница 19: ...ont Panel Configuration LED Description Link Speed Green 100Mbps Amber 1000Mbps Activity Flashing Amber Network Activity Power Status Green Power On Future Option Reserved for future use SSD Status Fl...

Страница 20: ...Oracle Talari E100 Hardware Guide Port Description 1 Gigabit Ethernet Bypass pair with Port 2 2 Gigabit Ethernet Bypass pair with Port 1 AUX Gigabit Ethernet Non bypass Used for Manual Installation M...

Страница 21: ...orage Temperature 40 F to 158 F 40 C to 70 C Humidity Range 5 to 90 non condensing operating environment Capacity 4 individual Gigabit Ethernet Ports User interfaces 2 USB 2 0 ports 1 RJ 45 Console Po...

Страница 22: ...iance To attach the ear brackets follow the instructions below Each ear bracket has three holes which align with matching holes on the appliance Align the holes in ear brackets with the holes in the a...

Страница 23: ...ppliance and older network devices that do not support Auto MDIX when straight through cables are used to connect the LAN and WAN ports of the Talari appliance In such a case a crossover cable is requ...

Страница 24: ...Overlay Description The E50 is deployed on the LAN side of the gateway and bypass pairs are configured as Fail To Wire Use this design if you prefer to retain existing edge devices or plan to install...

Страница 25: ...he E50 being deployed 4 Click the Edit pencil to open the Set Serial Number window 5 Enter the serial number of the E50 being deployed and click the Set Serial Number button Refer to Page 4 for assist...

Страница 26: ...e zipped client package to the on site user who will be deploying the appliance Deploying the Talari Appliance 1 Connect the power cord to the E50 Connect the other end to an appropriately grounded po...

Страница 27: ...2 7 Oracle Talari E100 Hardware Guide 7 Click Activate Staged to complete the process You may now restore the original network settings on your PC...

Страница 28: ...0 0 sdd Write Protect is off 4317967 864792 sd 6 0 0 0 sdd Mode Sense 45 00 00 00 4317967 864972 sd 6 0 0 0 sdd Write cache disabled read cache enabled doesn t support DPO or FUA In this case the dev...

Страница 29: ...nd requires root access and is prefixed with sudo sudo cp d6000v1_OS_7_0_1_0_0_GA_02282020_OS_52_GA_05022019_R8_2_1_0_0_GA_01282020 raw dev sdd 9 The USB burn process on a USB3 device can take 15 minu...

Страница 30: ...standalone program and requires no installation https rufus ie 3 Place the image on the USB drive Doing this destroys all existing data on the USB drive 4 Run Rufus You will be prompted to allow admin...

Страница 31: ...3 1 The USB burn process on a USB3 device can take 15 minutes It may take longer if the device or port is USB2 After the process is complete you can remove the USB It is ready for use...

Страница 32: ...into the USB port and power cycle the unit The E50 shown in the image above also has the management port connected in the LAN4 port 3 Enter the BIOS to set the USB stick to first in the boot order Ab...

Страница 33: ...talari 5 Use the Right Arrow to position to the Boot screen page once you are on the Main BIOS screen In the middle of the Boot screen is FIXED BOOT ORDER Priorities In the following example Boot Opti...

Страница 34: ...3 4 6 Use the Up and Down keys to select Boot Option 1 and press Enter You are presented with a pop up of available boot devices 7 Use the UP and DOWN keys to select the USB Device and press ENTER...

Страница 35: ...s the USB Device If Boot Option 2 is not the Hard Disk repeat the process on Boot Option 2 to set it to Hard Disk 8 Use the RIGHT arrow key and select the Save and Exit screen Select Save Changes and...

Страница 36: ...up from the USB flash device You will see the following GRUB screen press ENTER to continue 9 At the login prompt login as root when you see the standard Linux boot there is no password The Linux boot...

Страница 37: ...ed If this validation fails the files on the stick were corrupted and you cannot continue The verification will take less than 1 minute After validation the appliance will be identified and its model...

Страница 38: ...3 8...

Страница 39: ...mask width and optionally the gateway When these are to your satisfaction enter y that the configuration is correct Once you accept the IP4 configuration the installation script creates the partition...

Страница 40: ...4 0 When the reboot and second stage install is complete which may take around 5 minutes you can login to the appliance The appliance is ready for use...

Страница 41: ...lity is designed to prevent a single point of failure If there is a serious problem with the E50 APNA the bypass pair goes into bypass mode and forwards traffic through as though the appliance were a...

Отзывы: