Verify Card Status
4. Locate WarpDrive
5. Format WarpDrive
6. Show Vital Product Data
7. Extract SMART Logs
Select Operation [1-7 or 0:Quit]: 4
Enter Operation [1:on]:
Command Line Interface Usage:
Enter the following line of text in the CLI to run the
-
locate
command:
ddcli -c 1 -locate on
Related Information
■
Utility Command Summary” on page 38
■
“Troubleshooting Using Card LEDs” on page 54
Format Card Command
The
-format
command erases all of the data on the selected Sun Flash Accelerator F80 PCIe
Card.
Caution -
Data Loss. Use the -format command with caution, because it erases all of the data on
the card. Create a backup of all data before running this command.
Note -
Do not use this command unless directed by service personnel.
Text Menu Interface Usage
: The following top-level menu lists the cards in the system and
prompts you to select a card on which to perform an operation. Four Sun Flash Accelerator F80
PCIe Cards are shown in the following example:
# ddcli
****************************************************************
LSI Corporation WarpDrive Management Utility
Version 107.00.00.04 (2012.06.05)
Copyright (c) 2011 LSI Corporation. All Rights Reserved.
****************************************************************
ID WarpDrive Package Version PCI Address
-- --------- --------------- -----------
1 ELP-4x200-4d-n 09.05.24.00 00:02:00:00
2 ELP-4x200-4d-n 09.05.24.00 00:03:00:00
48
Sun Flash Accelerator F80 PCIe Card User's Guide • December 2013