Verify Card Status
4 ELP-4x200-4d-n 09.05.24.00 00:05:00:00
Select the WarpDrive [1-4 or 0:Quit]: 1
1. List WarpDrive Information
2. Update Flash Package
3. Display WarpDrive Health
4. Locate WarpDrive
5. Format WarpDrive
6. Show Vital Product Data
7. Extract SMART Logs
Select Operation [1-7 or 0:Quit]: 1
Command Line Interface Usage:
In CLI mode, select a Sun Flash Accelerator F80 PCIe Card
by including its card number (adapter index). Enter the following line of text in the CLI to run
the -list command:
ddcli -c 1 -list
Sample Output
: When the
-list
command runs, the
ddcli
utility outputs the following text:
# ddcli -c 1 -list
****************************************************************************
LSI Corporation WarpDrive Management Utility
Version 110.110.03.00 (2013.07.12)
Copyright (c) 2013 LSI Corporation. All Rights Reserved.
****************************************************************************
WarpDrive Selected is ELP-4x200-4d-n
------------------------------------------------------------------------
WarpDrive Information
------------------------------------------------------------------------
WarpDrive ID : 1
PCI Address : 00:03:00:00
PCI Slot Number : 0x05
PCI SubSystem DeviceId : 0x50A
PCI SubSystem VendorId : 0x108E
SAS Address : 500605B 00639C760
Package Version : 09.05.24.00
Firmware Version : 109.05.22.00
Legacy BIOS Version : 106.00.00.00
UEFI BSD Version : N/A
Chip Name : WarpDrive
Board Name : ELP-4x200-4d-n
Board Assembly Number : 03-25598-00B
Board Tracer Number : SP32232377
NUMA : Enabled
RAID Support : NO
------------------------------------------------------------------------
Servicing the Card
41