Verify Card Status
Command
Action
-format
Format the selected cards.
-showvpd
Show the Vital Product Data.
-getsmartlog
Extract the SMART Logs.
-help
Display help for command line usage. You do not need to select card number (-c).
-c
Card Number. Type the card ID option after the
ddcli
command to specify a card with an
ID number range from 1 to 256.
Related Information
■
List All Command
The
-listall
command identifies all Sun Flash Accelerator F80 PCIe Cards installed in a
server.
The following information is displayed with the
-listall
command:
■
Card ID number
■
Card name
■
Card flash package version
■
PCI address
Text Menu Interface Usage
: The
ddcli
utility lists seven commands. Type
1
to list all installed
Sun Flash Accelerator F80 PCIe Cards installed in a server, as shown in the following example:
# ddcli
1. List WarpDrive Information
2. Update Flash Package
3. Display WarpDrive Health
4. Locate WarpDrive
5. Format WarpDrive
6. Show Vital Product Data
7. Extract SMART Logs
Select Operation [1-7 or 0:Quit]: 1
Command Line Interface Usage:
Enter the following line of text in the CLI to run the
-
listall
command:
ddcli -listall
Servicing the Card
39