Verify Card Status
3 ELP-4x200-4d-n 09.05.24.00 00:04:00:00
4 ELP-4x200-4d-n 09.05.24.00 00:05:00:00
Select the WarpDrive [1-4 or 0:Quit]: 1
1. List WarpDrive Information
2. Update Flash Package
3. Display WarpDrive Health
4. Locate WarpDrive
5. Format WarpDrive
6. Show Vital Product Data
7. Extract SMART Logs
Select Operation [1-7 or 0:Quit]: 5
Enter whether to format single or all SSDs[1:Single 2:All or 0:Quit] 2
Perform Over-provisioning? (Yes/No): No
WARNING: Formatting will result in loss of all data on the selected WarpDrive device.
Type YES if you would like to continue, or any other key to abort the request: yes
LSI WarpDrive Management Utility: Please wait. Format of WarpDrive is in progress.....
LSI WarpDrive Management Utility: WarpDrive format successfully completed.
Select the WarpDrive [1-2 or 0:Quit]: 1
1. List WarpDrive Information
2. Update Flash Package
3. Display WarpDrive Health
4. Locate WarpDrive
5. Format WarpDrive
6. Show Vital Product Data
7. Extract SMART Logs
Select Operation [1-7 or 0:Quit]: 1
Command Line Interface Usage:
Enter either of the following lines of text in the CLI to run
the
-format
command:
ddcli -c 1 -format
or
dccli -c 1 -format -s
The
-s
option for the
-format
command activates silent mode. In silent mode, the
ddcli
utility
does not require confirmation before running the -format command.
If the
-s
option is not specified, the
ddcli
utility prompts you for confirmation before running
the command.
Related Information
■
Utility Command Summary” on page 38
Servicing the Card
49