Chapter 3
Servicing Server Module Components
3-11
3.1.5
Removing Flash Modules
Two Flash Module (FMOD) slots are located on the motherboard of the server
module.
Note –
CRU
: This customer replaceable unit can be replaced by anyone.
1. If necessary, back up any data that is contained on the Flash Module (FMOD).
2. Prepare the server module for service.
a. Power off both server module compute nodes.
See
Section 2.4, “Powering Off the Server Module” on page 2-4
.
b. Remove the server module from the Sun Blade chassis. Place it on a flat
surface.
See
Section 2.5, “Removing the Server Module From the Sun Blade Chassis” on
page 2-7
.
c. Attach an antistatic wrist strap.
See
Section 2.6, “Performing Electrostatic Discharge and Antistatic Prevention
Measures” on page 2-9
.
d. Remove the server module top cover.
See
Section 2.7, “Removing the Server Module Top Cover” on page 2-11
.
3. Locate the FMOD slot on the motherboard. See
FIGURE 3-6
, [1].
A lit green LED next to an FMOD slot indicates that the FMOD slot is powered on.
It does not indicate a faulty FMOD. Wait for the FMOD LED to go off before
installing or removing an FMOD to avoid damaging the FMOD.
4. Wait for the green FMOD LED to go out (about 20 seconds). See
FIGURE 3-6
, [2].
Caution –
Do not remove or insert the flash module until the green LED goes out.
Damage to the flash module can occur if the module is removed while the green LED
is lit.
5. Rotate both FMOD slot ejectors outward as far as they will go.
This action partially ejects the FMOD from the slot.
6. Carefully lift the FMOD straight up to remove it from the slot. See
FIGURE 3-6
,
[3].
Содержание Sun Blade X6275
Страница 1: ...Sun Blade X6275 Server Module Service Manual Part No Part No 820 6849 16 September 2013 Rev A ...
Страница 26: ...1 16 Sun Blade X6275 Server Module Service Manual September 2013 ...
Страница 47: ...Chapter 3 Servicing Server Module Components 3 7 FIGURE 3 3 DIMM Numbering and Position ...
Страница 54: ...3 14 Sun Blade X6275 Server Module Service Manual September 2013 FIGURE 3 7 Replacing Flash Modules ...
Страница 59: ...Chapter 3 Servicing Server Module Components 3 19 FIGURE 3 10 Processor Fault LEDs and Remind Button Locations ...
Страница 61: ...Chapter 3 Servicing Server Module Components 3 21 FIGURE 3 11 Removing a Processor ...
Страница 64: ...3 24 Sun Blade X6275 Server Module Service Manual September 2013 FIGURE 3 12 Replacing a Processor ...
Страница 72: ...3 32 Sun Blade X6275 Server Module Service Manual September 2013 FIGURE 3 14 Removing the RTC Batteries ...
Страница 80: ...3 40 Sun Blade X6275 Server Module Service Manual September 2013 ...
Страница 86: ...4 6 Sun Blade X6275 Server Module Service Manual September 2013 ...
Страница 90: ...A 4 Sun Blade X6275 Server Module Service Manual September 2013 FIGURE A 1 BIOS Utility Menu Tree ...
Страница 107: ...Appendix A BIOS Screens A 21 FIGURE A 29 BIOS Setup Utility Chipset FIGURE A 30 BIOS Setup Utility Chipset CPU Bridge ...
Страница 112: ...A 26 Sun Blade X6275 Server Module Service Manual September 2013 ...
Страница 116: ...Index 4 Sun Blade X6275 Server Module Service Manual September 2013 ...