el01cn02# dladm show-ib
LINK HCAGUID PORTGUID PORT STATE PKEYS
ibp0 21280001A0A694 21280001A0A695 1 up FFFF
ibp1 21280001A0A694 21280001A0A696 2 up FFFF
In the output, information about two ports is displayed. From this output,
you must determine which port GUID to use. This example procedure uses
the port GUID
21280001A0A695
(port 1).
b.
On the same compute node, run the following command on the command
line to report information about all active links in the InfiniBand fabric:
el01cn02# iblinkinfo.pl -R | grep hostname
Where
hostname
is the name of the compute node. For example,
el01cn02
.
The following is the example output of this command:
el01cn02# iblinkinfo.pl -R | grep el01cn02
65 15[ ] ==( 4X 10.0 Gbps Active/ LinkUp)==> 121 2[ ] "el01cn02
EL-C 192.168.10.29 HCA-1" (Could be 5.0 Gbps)
64 15[ ] ==( 4X 10.0 Gbps Active/ LinkUp)==> 120 1[ ] "el01cn02
EL-C 192.168.10.29 HCA-1" (Could be 5.0 Gbps)
From this example output, note down the switch lid values. The switch lid of
port 1 is
64
(the first column in the output). The switch lid of port 2 is
65
.
4.
Determine which gateway switch is associated with the switch lids by comparing
the first column of the
iblinkinfo
output to the lid value of the
ibswitches
command as follows:
a.
On the compute node, run the
ibswitches
command on the command line.
The example output of this command is as follows:
el01cn02# ibswitches
Switch : 0x002128548042c0a0 ports 36 "SUN IB QDR GW switch el01gw03"
enhanced port 0 lid 63 lmc 0
Switch : 0x002128547f22c0a0 ports 36 "SUN IB QDR GW switch el01gw02"
enhanced port 0 lid 6 lmc 0
Switch : 0x00212856d0a2c0a0 ports 36 "SUN IB QDR GW switch el01gw04"
enhanced port 0 lid 65 lmc 0
Switch : 0x00212856d162c0a0 ports 36 "SUN IB QDR GW switch el01gw05"
enhanced port 0 lid 64 lmc 0
b.
In this example output, identify the switches that lid values
64
and
65
are
associated with. In this example, the switch lid
64
of the gateway switch
el01gw05
with GUID
0x00212856d162c0a0
is associated with port 1 of
the HCA in the compute node
el01cn02
.
Note:
This example procedure uses LID
64
of this gateway switch.
5.
Define a dummy MAC address in the following format:
<last three octets from el01gw05 switch ib GUID> : <last
three octets of the administrative IP of the compute node in
hexadecimal format>
Example
:
Set Up Ethernet Over InfiniBand (EoIB) on Oracle Solaris
10-8 Oracle Exalogic Elastic Cloud Machine Owner's Guide
Содержание Exalogic Elastic Cloud
Страница 12: ...xii ...
Страница 70: ...Default Port Assignments 4 16 Machine Owner s Guide ...
Страница 82: ...Initial Network Configuration of Exalogic Machine 5 12 Machine Owner s Guide ...
Страница 102: ...Network Configuration Worksheets 6 20 Machine Owner s Guide ...
Страница 112: ...What Next 7 10 Machine Owner s Guide ...
Страница 134: ...Use the Phone Home Service to Manage the Storage Appliance 8 22 Machine Owner s Guide ...
Страница 162: ...Oracle Solaris Creating VNICs and Associating Them with VLANs 11 6 Machine Owner s Guide ...
Страница 248: ...Using Oracle Services in Oracle Enterprise Manager Ops Center 17 34 Oracle Exalogic Elastic Cloud Machine Owner s Guide ...
Страница 250: ...Using Oracle Services in Oracle Enterprise Manager Ops Center 17 36 Machine Owner s Guide ...
Страница 324: ...Power Distribution Unit Cabling Tables E 32 Machine Owner s Guide ...
Страница 338: ...Migrate a Zone to a New Host F 14 Machine Owner s Guide ...
Страница 342: ...Install Update and Remove RPMs Using Yum G 4 Machine Owner s Guide ...