Remove the Right LED/USB Indicator Module
4.
Remove the fan modules from the server.
“Remove a Fan Module” on page 67
.
5.
Disconnect all cables from the front storage drive backplane.
See the procedures for your storage drive configuration in
6.
Disconnect the left LED indicator module cable and the right LED/USB indicator
module cable from the motherboard [1 and 2].
7.
Slide the disk cage assembly forward, and then gently lift the disk cage
assembly from the chassis [3].
Set the disk cage assembly on an anti-static mat.
8.
Remove the right LED/USB indicator module.
Servicing Components That Require Server Power-Off
139