Remove the Sun Storage 12 Gb/s SAS PCIe RAID HBA Card
4.
Rotate the PCIe card locking mechanism, and then lift up on the PCIe HBA card
to disengage it from the motherboard connectors [1].
5.
Disconnect the super capacitor cable and the SAS cables from the Oracle
Storage 12 Gb/s SAS PCIe RAID HBA card [2].
“Remove SAS Storage Drive Cables” on page 118
6.
Lift and remove the Oracle Storage 12 Gb/s SAS PCIe RAID HBA card and super
capacitor cable from the chassis.
7.
Place the Oracle Storage 12 Gb/s SAS PCIe RAID HBA card and super capacitor
cable on an antistatic mat.
126
Oracle Exadata Storage Server X5-2 High Capacity Service Manual • January 2018