Memory Events
Messages and Descriptions
Component Name
Oracle ILOM Event Message:
event fault.memory.intel.dimm.memtest-failed "All memory
channels have been disabled due to memory test failures."
Severity and Description:
Major; A memory component is suspected of causing a fault.
SNMP Trap:
sunHwTrapMemoryFaultCleared
Oracle ILOM Event Message:
event fault.memory.intel.dimm.memtest-failed "All memory
channels have been disabled due to memory test failures."
Severity and Description:
Informational; A memory component fault has been cleared.
/SYS/MB
SNMP Trap:
sunHwTrapMemoryFault
Oracle ILOM Event Message:
event fault.memory.intel.dimm.quadrank-3rd-slot "A quad-rank
memory DIMM has been installed in the third slot of a memory channel."
Severity and Description:
Major; A memory component is suspected of causing a fault.
/SYS/MB
SNMP Trap:
sunHwTrapMemoryFaultCleared
Oracle ILOM Event Message:
event fault.memory.intel.dimm.quadrank-3rd-slot "A quad-rank
memory DIMM has been installed in the third slot of a memory channel."
Severity and Description:
Informational; A memory component fault has been cleared.
/SYS/MB
SNMP Trap:
sunHwTrapMemoryFault
Oracle ILOM Event Message:
event fault.memory.intel.dimm.ddr3u-unsupported "An
unsupported DDR3 ultra low voltage memory DIMM has been detected."
Severity and Description:
Major; A memory component is suspected of causing a fault.
/SYS/MB
SNMP Trap:
sunHwTrapMemoryFaultCleared
Oracle ILOM Event Message:
event fault.memory.intel.dimm.ddr3u-unsupported "An
unsupported DDR3 ultra low voltage memory DIMM has been detected."
Severity and Description:
Informational; A memory component fault has been cleared.
/SYS/MB
SNMP Trap:
sunHwTrapMemoryFault
Oracle ILOM Event Message:
event fault.memory.intel.mrc.unknown-errcode "An unknown
error code from the Memory Reference Code (MRC) has been detected."
Severity and Description:
Major; A memory component is suspected of causing a fault.
/SYS/MB
SNMP Trap:
sunHwTrapMemoryFaultCleared
Oracle ILOM Event Message:
event fault.memory.intel.mrc.unknown-errcode "An unknown
error code from the Memory Reference Code (MRC) has been detected."
Severity and Description:
Informational; A memory component fault has been cleared.
/SYS/MB
SNMP Trap:
sunHwTrapMemoryFault
Oracle ILOM Event Message:
event fault.memory.intel.dimm.udimm-unsupported "An
unbuffered memory DIMM (UDIMM) has been detected."
Severity and Description:
Major; A memory component is suspected of causing a fault.
/SYS/MB/P[0-
x
]/D[0-11]
Monitoring Components and Identifying SNMP Messages
251
Содержание EXADATA X5-2
Страница 1: ...Oracle Exadata Storage Server X5 2 High Capacity Service Manual Part No E55080 05 January 2018 ...
Страница 2: ......
Страница 12: ...12 Oracle Exadata Storage Server X5 2 High Capacity Service Manual January 2018 ...
Страница 20: ...20 Oracle Exadata Storage Server X5 2 High Capacity Service Manual January 2018 ...
Страница 160: ...160 Oracle Exadata Storage Server X5 2 High Capacity Service Manual January 2018 ...
Страница 176: ...176 Oracle Exadata Storage Server X5 2 High Capacity Service Manual January 2018 ...
Страница 202: ...202 Oracle Exadata Storage Server X5 2 High Capacity Service Manual January 2018 ...
Страница 228: ...228 Oracle Exadata Storage Server X5 2 High Capacity Service Manual January 2018 ...