78
-
XHEAD
Setup of the
Ambient temperature compensation
. In dependence on the emissivity
value of the object a certain amount of ambient radiation will be reflected from the object
surface. To compensate this impact, this function allows the setup of a fixed value which
represents the ambient radiation. If
XHEAD
is shown the ambient temperature value will
be taken from the head-internal probe. To return to
XHEAD
press
Up
and
Down
together.
M 01
Setup of the
Multidrop address
. In a RS485 network each sensor will need a specific
address. This menu item will only be shown if a RS485 interface board is plugged in. For
using the
RS422
mode, press once the down button on M01.
B 9.6
Setup of the
Baud rate
for digital data transfer.
Especially if there is a big difference between the ambient temperature at
the object and the head temperature the use of
ambient temperature
compensation
is recommended.