background image

Zone thermostat for 2-pipe fancoil with 0-10 Vdc fan regulation and 

valve management 

User manual

 

 

 

Thank you for choosing the zone thermostat for 2-pipe fan coils with 0-10 Vdc fan regulation 
and valve management. Z-Wave certified, the device is compatible with the gateways of the 
MyVirtuoso Home home automation system.

 

 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

www.myvirtuosohome.com

 

www.smartdhome.com

 

 
 

Содержание MyVirtuoso Home Zone Thermostat

Страница 1: ...ement User manual 1 Thank you for choosing the zone thermostat for 2 pipe fan coils with 0 10 Vdc fan regulation and valve management Z Wave certified the device is compatible with the gateways of the MyVirtuoso Home home automation system www myvirtuosohome com www smartdhome com ...

Страница 2: ...peed based on the temperature difference This product can be included and used in any Z Wave network with other Z Wave certified devices Features Power supply 230V 50 60HZ Resistive load 3A Self consumption 1W Fan regulation 0 10 Vdc Temperature sensor NTC 10K Display accuracy 0 1 C Work environment 0 55 C 95 RH not condensed Temperature setting 5 35 C adjustable Dimension 86 86 42mm Electrical bo...

Страница 3: ...Insert all wires into the appropriate terminals and tighten the screws The wiring diagram is shown below 3 Attach the wired device to points A of the steel frame as shown in the image then push it into the junction box 4 Check if the device is secure and switch on Wiring Diagram Buttons and Display 1 Temperature settings 2 Room temperature 3 Heating 4 Valve 1 2 3 4 Auto Lento Medio Veloce ...

Страница 4: ...ap M to enter working mode setting the current mode flashes Press or to switch between Cooling Heating and Ventilation modes then press M or wait 15 seconds to confirm your choice Ventilation mode settings In normal view press to switch between fan speeds Low Medium High Auto Then press M or wait 15s to confirm the choice Manual fan control If you decide to manually set the fan speed the device He...

Страница 5: ...s and hold to access the inclusion interface The display will show 2 Press once and the device will enter into ID search mode The inclusion will be successful if the ID is displayed on the screen Note after inclusion the device must be turned off and on again Exclusion Before starting the procedure for excluding the device in a Z Wave network check that it is turned on then make sure that the MyVi...

Страница 6: ...n damaging health and well being When replacing old appliances with new ones the retailer is legally obliged to accept the old appliance for free disposal Warranty and customer support Visit our website http www ecodhome com acquista garanzia eriparazioni html If you encounter technical problems or malfunctions visit the site http helpdesk smartdhome com users register aspx After a short registrat...