OPTOTRONIX SkyFire LCU Скачать руководство пользователя страница 7

 

+

‐ 

LED

 ‐ 

Outputs

 

Assignment

 

of

 

outputs

 

The

 

SkyFire

 

LCU

 

provides

 

a

 

total

 

of

 

9

 

light

 

channels

 

(each

 

Plus

 

/

 

Minus

).

 

The

 

input

 

voltage

 

(of

 

the

 

used

 

battery)

 

is

 

located

 

directly

 

at

 

the

 

outputs.

 

Through

 

this

 

the

 

maximum

 

flexibility

 

in

 

the

 

design

 

of

 

the

 

lighting

 

system

 

and

 

the

 

selection

 

of

 

LED

types

 

is

 

ensured.

 

The

 

outputs

 

have

 

a

 

joint

 

Plus

rail,

 

i.e.

 

PLUS

 

lines

 

can

 

be

 

connected

 

together

 

in

 

the

 

wing

 

area.

 

 

The

 

following

 

diagram

 

shows

 

the

 

output

 

assignment:

 

 

Outputs

 

 

1

 

2

 

3

 

4

 

5

 

6

 

7

 

8

 

9

 

AUX

 

EXT

 

 

 

 

 

 

 

 

 

‐ 

‐ 

‐ 

‐ 

‐ 

‐ 

‐ 

‐ 

‐ 

‐ 

 

+

 

+

 

+

 

+

 

+

 

+

 

+

 

+

 

+

 

+

 

 

 

Connection

 

of

 

LEDs

 

The

 

SkyFire

 

LCU

 

enables

 

the

 

operation

 

of

 

all

 

common

 

types

 

of

 

LEDs

 

with

 

matching

 

series

 

resistor

 

whereby

 

each

 

output

 

can

 

be

 

loaded

 

with

 

a

 

current

 

of

 

up

 

to

 

3

 

A.

 

Multiple

 

LEDs

 

can

 

be

 

connected

 

in

 

parallel

 

to

 

an

 

output,

 

while

 

each

 

LED

 

requires

 

its

 

own

 

resistor.

  

  

The

 

opposite

 

graph

 

shows

 

the

 

polarity

 

of

 

SEOUL

 

1W

 

/

 

3W

 

power

 

LEDs:

 

Next

 

to

 

each

 

pole

 

is

 

a

 

small

 

brass

 

stub.

 

This

 

is

 

notched

 

on

 

the

 

minus

 

side

 

and

 

not

 

on

 

the

 

plus

 

side.

 

 

Using

 

Typical

 

3mm

 

/

 

5mm

 

LEDs,

 

the

 

longer

 

connection

 

is

 

the

 

positive

 

terminal.

  

 

Using

 

typical

 

Superflux

 

LEDs

 

you

 

recognize

 

the

 

negative

 

terminal

 

at

 

the

 

flattened

 

corner.

 

Four

 

connections

 

are

 

available

 

here

 

only

 

for

 

stability

 

reasons,

 

plus

 

and

 

minus

 

are

 

each

 

present

 

in

 

duplicate,

 

but

 

must

 

be

 

connected

 

to

 

the

 

power

 

supply

 

once.

 

 

If

 

several

 

LEDs

 

are

 

connected

 

in

 

parallel

 

to

 

an

 

output,

 

the

 

PLUS

 

lines

 

can

 

be

 

combined

 

.

 

 

Due

 

to

 

the

 

large

 

current

 

carrying

 

capacity

 

of

 

SkyFire

 

LCU

 

the

 

outputs

 

are

 

designed

 

as

 

socket

 

(female),

 

so

 

that

 

a

 

short

 

circuit

 

is

 

not

 

possible

 

through

 

accidental

 

contact.

 

The

 

connection

 

of

 

LEDs

 

takes

 

place

 

via

 

the

 

provided

 

pin

 

bar.

 

For

 

easy

 

soldering

 

of

 

the

 

lines,

 

insert

 

the

 

bar

 

into

 

the

 

socket

 

of

 

the

 

SkyFire

 

LCU

.

 

Nevertheless,

 

if

 

the

 

contact

 

via

 

separate

 

plugs

 

for

 

each

 

channel

 

light

 

is

 

preferred,

 

the

 

optional

 

available

 

connector

 

kit

 

can

 

be

 

used.

 

 
 
 
 

+

 

+

 

Содержание SkyFire LCU

Страница 1: ...FINEST SCALE LIGHTING TECHNICS Manual...

Страница 2: ...quality 10 Check reception quality with Dual Receiver systems 11 Stand Alone mode 12 Programming mode 12 Starting the programming mode 12 Step 1 Select battery type 12 Step 2 Programming the light cha...

Страница 3: ...nal loads up to 8A 1 EXT output for optional accessories 3A output max 12A total current 10 different flash sequences 3 different points of time 4 beacon functions imitation of Rotating Beacon Afterbu...

Страница 4: ...Signal can be forwarded using the second socket Signal Input 2 AUX Signal to control the AUX Output switching afterburner rings or external loads Wake up via receiver signal Status LED Signal Input 1...

Страница 5: ...f individual LEDs IMPORTANT Voltages up to 13 0 V supply must only be connected to the AUX output AUX and not to the LCU itself LCU The maximum operating voltage of the LCU itself LCU is 8 5 V Do not...

Страница 6: ...polarity PLUS RED MINUS BLACK The MPX connectors to be used are labelled with and The correct polarity must be checked again before the first start up The SkyFire LCU is not reverse polarity protected...

Страница 7: ...larity of SEOUL 1W 3W power LEDs Next to each pole is a small brass stub This is notched on the minus side and not on the plus side Using Typical 3mm 5mm LEDs the longer connection is the positive ter...

Страница 8: ...rner rings individual LEDs or 12V LED strips can be controlled with an after burner effect as long as they can be operated at a voltage of 3 2 V 13 0 V AUX output The maximum current of AUX output is...

Страница 9: ...t voltage has to be converted into heat in the series resistor That is why the operation at 3 6V 4 8V 3s 4s NiMh or 3 7V 2s Lipo has to be preferred Operation of SkyFire LCU Start sequence If you pres...

Страница 10: ...tical threshold voltage for several seconds depending on the connected and programmed battery type the SkyFire LCU turns off completely in order to avoid a deep discharge of the battery and thus to pr...

Страница 11: ...ture is the indication of signal interference during flight If the model is in FailSafe mode due to signal interference the SkyFire LCU steps into the emergency lighting mode All outputs of the SkyFir...

Страница 12: ...Turn on the SkyFire LCU Keep the Set button permanently pressed before the welcoming sequence is completed Start of the programming mode is displayed through a 3 second long white flashing of the MODE...

Страница 13: ...orange status LED and the LED connected to the light channel display the sequence Activation point Storing the activation point and light sequence for each output By pressing the Set button you can za...

Страница 14: ...ng rotation beacon using dimming effect 34 Beacon 40 dimmed Flash IMPORTANT Connect flashing lights beacons beginning at output 1 and landing lights backwards starting from the output no 9 The SkyFire...

Страница 15: ...oads 1 Afterburner Effect random flickering without dimming up 2 Afterburner Effect random flickering slowly dimming up 3 Afterburner Effect random flickering fast dimming up 4 Afterburner Effect rand...

Страница 16: ...If you exit the programming mode now the monitoring of the reception quality is switched OFF Green flashing means that the actual signal value of the receiver is suitable as a fail safe signal If you...

Страница 17: ...ew about the different steps of programming mode short chose battery type 2s long Start of Programming Mode Display SW Version 1sec Programming Battery Type 1 LCU Programmiing Battery Type 2 AUX Progr...

Страница 18: ...ve to do a transceiver range test just as for every new built in electronic The distance of the SkyFire LCU to the receiver has to be maximized just as for every built in electronic 1 The 2 second lon...

Страница 19: ...ume no liability Further claims are excluded The product is used only for model aircrafts The SkyFire LCU has been suppressed by constructive measures Negative influences on the quality of receiving c...

Страница 20: ...CU the 9 light channels Y Cable Status LED Signal Input 1 blue Status LED Signal Input 2 blue MODE LED Multi Color Button Power on off Status LEDs For 9 light channels and AUX output orange Display Sc...

Отзывы: