OPTOTRONIX SkyFire LCU Скачать руководство пользователя страница 11

11 

 

 

 

Display

 

Quality

 

Using

 

the

 

10

 

orange

 

Status

 

LEDs,

 

the

 

quality

 

of

 

reception

 

is

 

now

 

displayed

 

on

 

a

 

scale

 

from

 

1

 

to

 

10.

 

For

 

illustration

 

the

 

reception

quality

scale

 

is

 

used:

 

 

 

The

 

quality

 

should

 

generally

 

be

 

in

 

the

 

green

 

zone

 

(8

 

to

 

10),

 

otherwise

 

the

 

receiving

 

system

 

should

 

be

 

checked

 

and

 

optimized.

 

The

 

limit

 

value

 

8

 

corresponds

 

to

 

a

 

signal

 

failure

 

of

 

<1

 

sec

 

over

 

the

 

entire

 

period

 

of

 

(flight)

 

operation.

 

 

Display

 

signal

 

failures

 

If

 

desired,

 

press

 

the

 

set

 

button

 

briefly

 

again

 

during

 

the

 

display

 

of

 

reception

 

quality

 

(see

 

above)

 

 

.

    

Again

 

the

 

10

 

orange

 

Status

 

LEDs

 

show

 

the

 

antenna

 

sequence,

 

but

 

quickly

 

flashing,

 

the

 

MODE

 

LED

 

light

 

is

 

red

.

 

This

 

illustrates,

 

that

 

now

 

the

 

signal

 

failures

 

(error

 

frames)

 

will

 

be

 

displayed.

 

For

 

illustration

 

the

 

Error

Frame

 

scale

 

is

 

used:

 

 

 

The

 

little

 

red

 

numbers

 

in

 

the

 

bottom

 

row

 

represent

 

the

 

number

 

of

 

lost

 

signal

frames.

 

The

 

number

 

should

 

generally

 

be

 

less

 

than

 

50

  

(after

 

a

 

flight),

 

otherwise

 

the

 

receiving

 

system

 

should

 

be

 

checked

 

and

 

optimized.

 

 

A

 

very

 

important

 

and

 

useful

 

feature

 

is

 

the

 

indication

 

of

 

signal

 

interference

 

during

 

flight

.

 

If

 

the

 

model

 

is

 

in

 

FailSafe

mode

 

due

 

to

 

signal

 

interference,

 

the

 

SkyFire

 

LCU

 

steps

 

into

 

the

 

emergency

 

lighting

 

mode.

 

All

 

outputs

 

of

 

the

 

SkyFire

 

LCU

 

blink

 

very

 

fast,

 

followed

 

by

 

a

 

short

 

break

 

every

 

2

 

seconds.

 

This

 

behavior

 

is

 

exactly

 

of

 

the

 

same

 

length

 

like

 

the

 

fault

 

(the

 

FailSafe

 

phase),

 

but

 

at

 

least

 

2

 

seconds.

 

 

IMPORTANT:

 

The

 

display

 

of

 

reception

 

quality

 

and

 

signal

 

failures

 

is

 

an

 

indication

 

for

 

possible

 

optimizations

 

of

 

the

 

receiving

 

system

 

or

 

of

 

its

 

set

up

 

/

 

orientation.

 

The

 

notifications

 

are

 

no

 

guarantee

 

for

 

an

 

optimal

 

reception

 

and

 

safe

 

operation

 

of

 

the

 

receiving

 

system.

 

 

Check

 

reception

 

quality

 

with

 

Dual

Receiver

 

systems

 

If

 

a

 

dual

receiver

 

system

 

is

 

used

 

in

 

the

 

model,

 

connect

 

the

 

two

 

inputs

 

of

 

SkyFire

 

LCU

 

to

 

each

 

one

 

of

 

the

 

two

 

receivers.

 

The

 

SkyFire

 

LCU

 

recognizes

 

the

 

different

 

measurement

 

results

 

of

 

the

 

two

 

inputs

 

and

 

then

 

displays

 

the

 

quality

 

of

 

reception

 

twice

 

in

 

a

 

row.

 

First,

 

for

 

input

 

1,

 

then

 

for

 

input

 

2

 

(The

 

respective

 

input

 

flashes

 

during

 

the

 

quality

 

display).

  

This

 

makes

 

it

 

possible

 

to

 

optimize

 

the

 

location

 

of

 

each

 

receiver

 

/

 

antenna

 

in

 

terms

 

of

 

reception

 

quality.

 

To

 

do

 

this,

 

check

 

the

 

receiving

 

quality

 

regularly.

 

X

Содержание SkyFire LCU

Страница 1: ...FINEST SCALE LIGHTING TECHNICS Manual...

Страница 2: ...quality 10 Check reception quality with Dual Receiver systems 11 Stand Alone mode 12 Programming mode 12 Starting the programming mode 12 Step 1 Select battery type 12 Step 2 Programming the light cha...

Страница 3: ...nal loads up to 8A 1 EXT output for optional accessories 3A output max 12A total current 10 different flash sequences 3 different points of time 4 beacon functions imitation of Rotating Beacon Afterbu...

Страница 4: ...Signal can be forwarded using the second socket Signal Input 2 AUX Signal to control the AUX Output switching afterburner rings or external loads Wake up via receiver signal Status LED Signal Input 1...

Страница 5: ...f individual LEDs IMPORTANT Voltages up to 13 0 V supply must only be connected to the AUX output AUX and not to the LCU itself LCU The maximum operating voltage of the LCU itself LCU is 8 5 V Do not...

Страница 6: ...polarity PLUS RED MINUS BLACK The MPX connectors to be used are labelled with and The correct polarity must be checked again before the first start up The SkyFire LCU is not reverse polarity protected...

Страница 7: ...larity of SEOUL 1W 3W power LEDs Next to each pole is a small brass stub This is notched on the minus side and not on the plus side Using Typical 3mm 5mm LEDs the longer connection is the positive ter...

Страница 8: ...rner rings individual LEDs or 12V LED strips can be controlled with an after burner effect as long as they can be operated at a voltage of 3 2 V 13 0 V AUX output The maximum current of AUX output is...

Страница 9: ...t voltage has to be converted into heat in the series resistor That is why the operation at 3 6V 4 8V 3s 4s NiMh or 3 7V 2s Lipo has to be preferred Operation of SkyFire LCU Start sequence If you pres...

Страница 10: ...tical threshold voltage for several seconds depending on the connected and programmed battery type the SkyFire LCU turns off completely in order to avoid a deep discharge of the battery and thus to pr...

Страница 11: ...ture is the indication of signal interference during flight If the model is in FailSafe mode due to signal interference the SkyFire LCU steps into the emergency lighting mode All outputs of the SkyFir...

Страница 12: ...Turn on the SkyFire LCU Keep the Set button permanently pressed before the welcoming sequence is completed Start of the programming mode is displayed through a 3 second long white flashing of the MODE...

Страница 13: ...orange status LED and the LED connected to the light channel display the sequence Activation point Storing the activation point and light sequence for each output By pressing the Set button you can za...

Страница 14: ...ng rotation beacon using dimming effect 34 Beacon 40 dimmed Flash IMPORTANT Connect flashing lights beacons beginning at output 1 and landing lights backwards starting from the output no 9 The SkyFire...

Страница 15: ...oads 1 Afterburner Effect random flickering without dimming up 2 Afterburner Effect random flickering slowly dimming up 3 Afterburner Effect random flickering fast dimming up 4 Afterburner Effect rand...

Страница 16: ...If you exit the programming mode now the monitoring of the reception quality is switched OFF Green flashing means that the actual signal value of the receiver is suitable as a fail safe signal If you...

Страница 17: ...ew about the different steps of programming mode short chose battery type 2s long Start of Programming Mode Display SW Version 1sec Programming Battery Type 1 LCU Programmiing Battery Type 2 AUX Progr...

Страница 18: ...ve to do a transceiver range test just as for every new built in electronic The distance of the SkyFire LCU to the receiver has to be maximized just as for every built in electronic 1 The 2 second lon...

Страница 19: ...ume no liability Further claims are excluded The product is used only for model aircrafts The SkyFire LCU has been suppressed by constructive measures Negative influences on the quality of receiving c...

Страница 20: ...CU the 9 light channels Y Cable Status LED Signal Input 1 blue Status LED Signal Input 2 blue MODE LED Multi Color Button Power on off Status LEDs For 9 light channels and AUX output orange Display Sc...