OPTOTRONIX SkyFire LCU Скачать руководство пользователя страница 12

12 

 

Stand

Alone

 

mode

  

This

 

"independent

 

operation

 

mode"

 

enables

 

the

 

operation

 

of

 

the

 

lighting

 

model,

 

even

 

if

 

the

 

receiving

 

system

 

is

 

not

 

turned

 

on

 

(e.g

 

exhibitions)

 

may

 

or

 

may

 

not

 

be

 

turned

 

on

 

(e.g.

 

during

 

competitive

 

building

 

rating).

 

In

 

Standalone

 

mode

 

 

the

 

MODE

 

LED

 

lights

 

pink

.

 

 

Activate

 

all

 

outputs

 

through

 

your

 

transmitters

 

which

 

should

 

be

 

constantly

 

active

 

and

 

then

 

keep

 

the

 

Set

 

button

 

pressed

 

for

 

at

 

least

 

2

 

seconds.

 

Pressing

 

the

 

button

 

for

 

long

 

will

 

always

 

be

 

confirmed

 

through

 

rapid

 

flashing

 

of

 

the

 

MODE

 

LED

 

twice.

  

The

 

MODE

 

LED

 

lights

 

permanently

 

pink,

 

the

 

Stand

 

alone

 

mode

 

 

is

 

active

 

and

 

the

 

electronics

 

no

 

longer

 

responds

 

to

 

the

 

signal

 

receiver!

   

Leave

 

the

 

Standalone

 

mode

 

and

 

also

 

press

 

the

 

Set

 

button

 

for

 

2

 

seconds

   

.

  

 

Programming

 

mode

 

 

The

 

following

 

explains

 

how

 

simply

 

the

 

SkyFire

 

LCU

 

must

 

be

 

programmed.

 

Starting

 

the

 

programming

 

mode

 

Connect

 

the

 

power

 

supply

 

and

 

the

 

receiver

 

or

 

servo

 

tester

 

to

 

the

 

SkyFire

 

LCU.

 

   

Turn

 

on

 

the

 

SkyFire

 

LCU.

 

Keep

 

the

 

Set

 

button

 

 

permanently

 

pressed,

 

before

 

the

 

welcoming

 

sequence

 

is

 

completed.

  

Start

 

of

 

the

 

programming

 

mode

 

is

 

displayed

 

through

 

a

 

3

 

second

 

long

 

white

 

flashing

 

of

 

the

 

MODE

 

LED

 

and

 

through

 

fast

 

flashing

 

of

 

all

 

orange

 

status

 

LEDs.

 

Release

 

the

 

button

 

again

 

when

 

the

 

flashing

 

starts.

 

You

 

are

 

now

 

in

 

programming

 

mode.

 

 
 

Step

 

1

 ‐ 

Select

 

battery

 

type

 

The

 

start

 

of

 

the

 

battery

 

type

 

programming

 

is

 

illustrated

 

by

 

a

 

sequence

 

of

 

traffic

 

lights

 

MODE

 

LED

 

(

 

green

 

‐ 

Orange

 

‐ 

red

 

,

 

"charging

status

 

traffic

 

light").

  

At

 

the

 

beginning,

 

you

 

will

 

need

 

to

 

program

 

the

 

battery

 

type

 

to

 

be

 

used

 

(lipo,

 

LiFePO,

 

"Other").

 

Connect

 

the

 

charged

 

battery

 

to

 

the

 

module

 

in

 

the

 

first

 

programming.

  

By

 

pressing

 

("zapping")

 

the

 

set

 

button

 

for

 

a

 

short

 

while

   

you

 

can

 

switch

 

between

 

the

 

three

 

variants,

 

for

 

signaling

 

two

 

of

 

the

 

status

 

LEDs

 

light

 

orange

.

 

Save

 

the

 

desired

 

type

 

by

 

pressing

 

the

 

Set

  

  

button

 

for

 

2

 

seconds.

 

The

 

number

 

of

 

cells

 

used

 

is

 

automatically

 

detected

.

  

If

 

you

 

select

 

"Other"

 

(e.g.

 

for

 

BEC

 

supply)

 

no

 

safety

 

shutdown

 

occurs,

 

the

 

battery

 

voltage

 

in

 

6

 

levels

 

from

 

3.2

 

to

 

8.5

 

V

 

is

 

only

 

displayed.

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

Lipo (factory

 

setting)

LiFePO

Others

 

(NiMH,

 

BEC)

Содержание SkyFire LCU

Страница 1: ...FINEST SCALE LIGHTING TECHNICS Manual...

Страница 2: ...quality 10 Check reception quality with Dual Receiver systems 11 Stand Alone mode 12 Programming mode 12 Starting the programming mode 12 Step 1 Select battery type 12 Step 2 Programming the light cha...

Страница 3: ...nal loads up to 8A 1 EXT output for optional accessories 3A output max 12A total current 10 different flash sequences 3 different points of time 4 beacon functions imitation of Rotating Beacon Afterbu...

Страница 4: ...Signal can be forwarded using the second socket Signal Input 2 AUX Signal to control the AUX Output switching afterburner rings or external loads Wake up via receiver signal Status LED Signal Input 1...

Страница 5: ...f individual LEDs IMPORTANT Voltages up to 13 0 V supply must only be connected to the AUX output AUX and not to the LCU itself LCU The maximum operating voltage of the LCU itself LCU is 8 5 V Do not...

Страница 6: ...polarity PLUS RED MINUS BLACK The MPX connectors to be used are labelled with and The correct polarity must be checked again before the first start up The SkyFire LCU is not reverse polarity protected...

Страница 7: ...larity of SEOUL 1W 3W power LEDs Next to each pole is a small brass stub This is notched on the minus side and not on the plus side Using Typical 3mm 5mm LEDs the longer connection is the positive ter...

Страница 8: ...rner rings individual LEDs or 12V LED strips can be controlled with an after burner effect as long as they can be operated at a voltage of 3 2 V 13 0 V AUX output The maximum current of AUX output is...

Страница 9: ...t voltage has to be converted into heat in the series resistor That is why the operation at 3 6V 4 8V 3s 4s NiMh or 3 7V 2s Lipo has to be preferred Operation of SkyFire LCU Start sequence If you pres...

Страница 10: ...tical threshold voltage for several seconds depending on the connected and programmed battery type the SkyFire LCU turns off completely in order to avoid a deep discharge of the battery and thus to pr...

Страница 11: ...ture is the indication of signal interference during flight If the model is in FailSafe mode due to signal interference the SkyFire LCU steps into the emergency lighting mode All outputs of the SkyFir...

Страница 12: ...Turn on the SkyFire LCU Keep the Set button permanently pressed before the welcoming sequence is completed Start of the programming mode is displayed through a 3 second long white flashing of the MODE...

Страница 13: ...orange status LED and the LED connected to the light channel display the sequence Activation point Storing the activation point and light sequence for each output By pressing the Set button you can za...

Страница 14: ...ng rotation beacon using dimming effect 34 Beacon 40 dimmed Flash IMPORTANT Connect flashing lights beacons beginning at output 1 and landing lights backwards starting from the output no 9 The SkyFire...

Страница 15: ...oads 1 Afterburner Effect random flickering without dimming up 2 Afterburner Effect random flickering slowly dimming up 3 Afterburner Effect random flickering fast dimming up 4 Afterburner Effect rand...

Страница 16: ...If you exit the programming mode now the monitoring of the reception quality is switched OFF Green flashing means that the actual signal value of the receiver is suitable as a fail safe signal If you...

Страница 17: ...ew about the different steps of programming mode short chose battery type 2s long Start of Programming Mode Display SW Version 1sec Programming Battery Type 1 LCU Programmiing Battery Type 2 AUX Progr...

Страница 18: ...ve to do a transceiver range test just as for every new built in electronic The distance of the SkyFire LCU to the receiver has to be maximized just as for every built in electronic 1 The 2 second lon...

Страница 19: ...ume no liability Further claims are excluded The product is used only for model aircrafts The SkyFire LCU has been suppressed by constructive measures Negative influences on the quality of receiving c...

Страница 20: ...CU the 9 light channels Y Cable Status LED Signal Input 1 blue Status LED Signal Input 2 blue MODE LED Multi Color Button Power on off Status LEDs For 9 light channels and AUX output orange Display Sc...

Отзывы: