OPTOTRONIX SkyFire LCU Скачать руководство пользователя страница 4

 

Interface

 

and

 

handling

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

MODE

LED

 

Color

 

Meaning:

 

GRÜN

 

Operation

 

Mode,

 

state

 

of

 

charge

 

>

 

40%

 

ORANGE

 

Operation

 

Mode,

 

state

 

of

 

charge

 

<

 

40%

 

ROT

 

Operation

 

Mode,

 

state

 

of

 

charge

 

critical

 

BLAU

 

Operation

 

Mode,

 

display

 

RQO

 

PINK

 

Stand

Alone

 

Mode

 

(showroom

 

mode)

 

WEISS

 

Start

 

programming

mode

 

 

MPX

 

Stecker

 

 

+

Signal

Input

 

1

 

(Master)

 

Signal

 

for

 

controlling

 

the

 

LCU

 

(the

  

9

 

light

 

channels)

 

 

Built

In

 

Y

Cable:

 

Signal

 

can

 

be

 

forwarded

 

using

 

the

 

second

 

socket

 

Signal

Input

 

2

 

(AUX)

 

Signal

 

to

 

control

 

the

 

AUX

 

Output,

 

switching

 

afterburner

 

rings

 

or

 

external

 

loads

 

 

Wake

up

 

via

 

receiver

 

signal

 

Status

LED

 

Signal

Input

 

1

 

blau

 

Status

LED

 

Signal

Input

 

2

 

blau

MODE

LED

 

Multicolor

 

Taster

 

„Set“

 

Button

 

„Power

 

on/off“

Status

LEDs

 

For

 

9

 

light

 

channels

 

and

 

AUX

 

Output,

 

orange

 

Display

Scale

 

For

 

displaying

 

the

 

batteries

 

state

of

charge

 

and

 

reception

 

quality

 

Button

 

„Set“

 

Light

 

Channels

 

(9x)

 

AUX

 

Output

 

Ext

 

Output

 

  

Spannungsversorgung

 

Supply LCU

 

(light

 

channels)

 

3,2V

 

 

8,5V

 

Supply

 

AUX

 

Output

3,2V

 

 

13,0V

 

Common MINUS

 

Содержание SkyFire LCU

Страница 1: ...FINEST SCALE LIGHTING TECHNICS Manual...

Страница 2: ...quality 10 Check reception quality with Dual Receiver systems 11 Stand Alone mode 12 Programming mode 12 Starting the programming mode 12 Step 1 Select battery type 12 Step 2 Programming the light cha...

Страница 3: ...nal loads up to 8A 1 EXT output for optional accessories 3A output max 12A total current 10 different flash sequences 3 different points of time 4 beacon functions imitation of Rotating Beacon Afterbu...

Страница 4: ...Signal can be forwarded using the second socket Signal Input 2 AUX Signal to control the AUX Output switching afterburner rings or external loads Wake up via receiver signal Status LED Signal Input 1...

Страница 5: ...f individual LEDs IMPORTANT Voltages up to 13 0 V supply must only be connected to the AUX output AUX and not to the LCU itself LCU The maximum operating voltage of the LCU itself LCU is 8 5 V Do not...

Страница 6: ...polarity PLUS RED MINUS BLACK The MPX connectors to be used are labelled with and The correct polarity must be checked again before the first start up The SkyFire LCU is not reverse polarity protected...

Страница 7: ...larity of SEOUL 1W 3W power LEDs Next to each pole is a small brass stub This is notched on the minus side and not on the plus side Using Typical 3mm 5mm LEDs the longer connection is the positive ter...

Страница 8: ...rner rings individual LEDs or 12V LED strips can be controlled with an after burner effect as long as they can be operated at a voltage of 3 2 V 13 0 V AUX output The maximum current of AUX output is...

Страница 9: ...t voltage has to be converted into heat in the series resistor That is why the operation at 3 6V 4 8V 3s 4s NiMh or 3 7V 2s Lipo has to be preferred Operation of SkyFire LCU Start sequence If you pres...

Страница 10: ...tical threshold voltage for several seconds depending on the connected and programmed battery type the SkyFire LCU turns off completely in order to avoid a deep discharge of the battery and thus to pr...

Страница 11: ...ture is the indication of signal interference during flight If the model is in FailSafe mode due to signal interference the SkyFire LCU steps into the emergency lighting mode All outputs of the SkyFir...

Страница 12: ...Turn on the SkyFire LCU Keep the Set button permanently pressed before the welcoming sequence is completed Start of the programming mode is displayed through a 3 second long white flashing of the MODE...

Страница 13: ...orange status LED and the LED connected to the light channel display the sequence Activation point Storing the activation point and light sequence for each output By pressing the Set button you can za...

Страница 14: ...ng rotation beacon using dimming effect 34 Beacon 40 dimmed Flash IMPORTANT Connect flashing lights beacons beginning at output 1 and landing lights backwards starting from the output no 9 The SkyFire...

Страница 15: ...oads 1 Afterburner Effect random flickering without dimming up 2 Afterburner Effect random flickering slowly dimming up 3 Afterburner Effect random flickering fast dimming up 4 Afterburner Effect rand...

Страница 16: ...If you exit the programming mode now the monitoring of the reception quality is switched OFF Green flashing means that the actual signal value of the receiver is suitable as a fail safe signal If you...

Страница 17: ...ew about the different steps of programming mode short chose battery type 2s long Start of Programming Mode Display SW Version 1sec Programming Battery Type 1 LCU Programmiing Battery Type 2 AUX Progr...

Страница 18: ...ve to do a transceiver range test just as for every new built in electronic The distance of the SkyFire LCU to the receiver has to be maximized just as for every built in electronic 1 The 2 second lon...

Страница 19: ...ume no liability Further claims are excluded The product is used only for model aircrafts The SkyFire LCU has been suppressed by constructive measures Negative influences on the quality of receiving c...

Страница 20: ...CU the 9 light channels Y Cable Status LED Signal Input 1 blue Status LED Signal Input 2 blue MODE LED Multi Color Button Power on off Status LEDs For 9 light channels and AUX output orange Display Sc...

Отзывы: