OPTOTRONIX SkyFire LCU Скачать руководство пользователя страница 16

16 

 

 
 
 
 

 
 
 
 
 
 
 
 
 
 
 

To

 

enable

 

the

 

monitoring

 

of

 

the

 

reception

 

quality

 

(RQO),

 

the

 

FailSafe

 

mode

 

of

 

the

 

lighting

 

channel

 

of

 

the

 

receiver

 

must

 

be

 

activated!

 

As

 

a

 

signal

 

level

 

for

 

the

 

FailSafe

 

Mode,

 

the

 

“deepest”

 

possible

 

(

‐ 

100%)

 

shall

 

be

 

programmed

 

in

 

the

 

transceiver.

 

It

 

is

 

important

 

that

 

the

 

FailSafe

 

level

 

is

 

smaller

 

than

 

the

 

smallest

 

point

 

of

 

activation

 

of

 

the

 

light

 

channels,

 

otherwise

 

the

 

normal

 

operation

 

mode

 

could

 

not

 

be

 

distinguished

 

from

 

the

 

Failsafe

 

mode.

 

 

The

 

MODE

 

LED

 

continuously

 

lights

 

up

 

blue

 

(RQO

 

display

 

mode)

 

and

 

flashes

 

once

 

per

 

second

 

shortly

 

red

 

or

 

green

 

:

 

 

 

 

Red

 

flashing

 

means

 

that

 

the

 

actual

 

signal

 

value

 

of

 

the

 

receiver

 

is

 

not

 

suitable

 

as

 

a

 

fail

safe

 

signal

 

because

 

this

 

value

 

is

 

in

 

the

 

range

 

of

 

pre

programmed

 

activation

 

points

 

of

 

the

 

light

 

channels.

  

 

If

 

you

 

exit

 

the

 

programming

 

mode

 

now,

 

the

 

monitoring

 

of

 

the

 

reception

 

quality

 

is

 

switched

 

OFF!

  

 

 

Green

 

flashing

 

means

 

that

 

the

 

actual

 

signal

 

value

 

of

 

the

 

receiver

 

is

 

suitable

 

as

 

a

 

fail

safe

 

signal

.

  

 

If

 

you

 

exit

 

the

 

programming

 

mode

 

now,

 

the

 

monitoring

 

of

 

the

 

reception

 

quality

 

is

 

switched

 

ON!

  

 

 

Change

 

the

 

FailSafe

 

Level

 

in

 

the

 

transceiver

 

(recommendation:

 ‐

100%)

 

until

 

the

 

MODE

 

LED

 

flashes

 

green.

 

  

Save

 

the

 

FailSafe

 

level

 

and

 

then

 

activate

 

the

 

reception

monitoring

 

mode

 

by

 

pressing

 

the

 

Set

 

button

  

  

 

for

 

2

 

seconds.

  

 

If

 

the

 

receiver

monitoring

 

mode

 

(RQO)

 

is

 

not

 

used,

 

terminate

 

the

 

programming

 

mode

 

by

 

turning

 

off

 

the

 

LCU

 

(if

 

the

 

reception

monitoring

 

was

 

not

 

previously

 

active)

 

or

 

disable

 

the

 

receiving

 

monitoring

 

by

 

deactivating

 

the

 

FailSafe

 

mode

 

in

 

the

 

transmitter

 

and

 

finishing

 

the

 

programming

 

mode

 

of

 

SkyFire

 

LCU

 

with

 

red

 

flashing

 

LED.

 

 

After

 

finishing

 

the

 

programming

 

mode,

 

the

 

SkyFire

 

LCU

 

restarts.

  

 

DONE

 ‐ 

The

 

SkyFire

 

LCU

 

is

 

now

 

fully

 

programmed

 

and

 

can

 

be

 

used.

 

 

Содержание SkyFire LCU

Страница 1: ...FINEST SCALE LIGHTING TECHNICS Manual...

Страница 2: ...quality 10 Check reception quality with Dual Receiver systems 11 Stand Alone mode 12 Programming mode 12 Starting the programming mode 12 Step 1 Select battery type 12 Step 2 Programming the light cha...

Страница 3: ...nal loads up to 8A 1 EXT output for optional accessories 3A output max 12A total current 10 different flash sequences 3 different points of time 4 beacon functions imitation of Rotating Beacon Afterbu...

Страница 4: ...Signal can be forwarded using the second socket Signal Input 2 AUX Signal to control the AUX Output switching afterburner rings or external loads Wake up via receiver signal Status LED Signal Input 1...

Страница 5: ...f individual LEDs IMPORTANT Voltages up to 13 0 V supply must only be connected to the AUX output AUX and not to the LCU itself LCU The maximum operating voltage of the LCU itself LCU is 8 5 V Do not...

Страница 6: ...polarity PLUS RED MINUS BLACK The MPX connectors to be used are labelled with and The correct polarity must be checked again before the first start up The SkyFire LCU is not reverse polarity protected...

Страница 7: ...larity of SEOUL 1W 3W power LEDs Next to each pole is a small brass stub This is notched on the minus side and not on the plus side Using Typical 3mm 5mm LEDs the longer connection is the positive ter...

Страница 8: ...rner rings individual LEDs or 12V LED strips can be controlled with an after burner effect as long as they can be operated at a voltage of 3 2 V 13 0 V AUX output The maximum current of AUX output is...

Страница 9: ...t voltage has to be converted into heat in the series resistor That is why the operation at 3 6V 4 8V 3s 4s NiMh or 3 7V 2s Lipo has to be preferred Operation of SkyFire LCU Start sequence If you pres...

Страница 10: ...tical threshold voltage for several seconds depending on the connected and programmed battery type the SkyFire LCU turns off completely in order to avoid a deep discharge of the battery and thus to pr...

Страница 11: ...ture is the indication of signal interference during flight If the model is in FailSafe mode due to signal interference the SkyFire LCU steps into the emergency lighting mode All outputs of the SkyFir...

Страница 12: ...Turn on the SkyFire LCU Keep the Set button permanently pressed before the welcoming sequence is completed Start of the programming mode is displayed through a 3 second long white flashing of the MODE...

Страница 13: ...orange status LED and the LED connected to the light channel display the sequence Activation point Storing the activation point and light sequence for each output By pressing the Set button you can za...

Страница 14: ...ng rotation beacon using dimming effect 34 Beacon 40 dimmed Flash IMPORTANT Connect flashing lights beacons beginning at output 1 and landing lights backwards starting from the output no 9 The SkyFire...

Страница 15: ...oads 1 Afterburner Effect random flickering without dimming up 2 Afterburner Effect random flickering slowly dimming up 3 Afterburner Effect random flickering fast dimming up 4 Afterburner Effect rand...

Страница 16: ...If you exit the programming mode now the monitoring of the reception quality is switched OFF Green flashing means that the actual signal value of the receiver is suitable as a fail safe signal If you...

Страница 17: ...ew about the different steps of programming mode short chose battery type 2s long Start of Programming Mode Display SW Version 1sec Programming Battery Type 1 LCU Programmiing Battery Type 2 AUX Progr...

Страница 18: ...ve to do a transceiver range test just as for every new built in electronic The distance of the SkyFire LCU to the receiver has to be maximized just as for every built in electronic 1 The 2 second lon...

Страница 19: ...ume no liability Further claims are excluded The product is used only for model aircrafts The SkyFire LCU has been suppressed by constructive measures Negative influences on the quality of receiving c...

Страница 20: ...CU the 9 light channels Y Cable Status LED Signal Input 1 blue Status LED Signal Input 2 blue MODE LED Multi Color Button Power on off Status LEDs For 9 light channels and AUX output orange Display Sc...

Отзывы: