16
To
enable
the
monitoring
of
the
reception
quality
(RQO),
the
FailSafe
mode
of
the
lighting
channel
of
the
receiver
must
be
activated!
As
a
signal
level
for
the
FailSafe
Mode,
the
“deepest”
possible
(
‐
100%)
shall
be
programmed
in
the
transceiver.
It
is
important
that
the
FailSafe
level
is
smaller
than
the
smallest
point
of
activation
of
the
light
channels,
otherwise
the
normal
operation
mode
could
not
be
distinguished
from
the
Failsafe
mode.
The
MODE
LED
continuously
lights
up
blue
(RQO
display
mode)
and
flashes
once
per
second
shortly
red
or
green
:
Red
flashing
means
that
the
actual
signal
value
of
the
receiver
is
not
suitable
as
a
fail
‐
safe
signal
because
this
value
is
in
the
range
of
pre
‐
programmed
activation
points
of
the
light
channels.
If
you
exit
the
programming
mode
now,
the
monitoring
of
the
reception
quality
is
switched
OFF!
Green
flashing
means
that
the
actual
signal
value
of
the
receiver
is
suitable
as
a
fail
‐
safe
signal
.
If
you
exit
the
programming
mode
now,
the
monitoring
of
the
reception
quality
is
switched
ON!
Change
the
FailSafe
Level
in
the
transceiver
(recommendation:
‐
100%)
until
the
MODE
LED
flashes
green.
Save
the
FailSafe
level
and
then
activate
the
reception
‐
monitoring
mode
by
pressing
the
Set
button
for
2
seconds.
If
the
receiver
‐
monitoring
mode
(RQO)
is
not
used,
terminate
the
programming
mode
by
turning
off
the
LCU
(if
the
reception
‐
monitoring
was
not
previously
active)
or
disable
the
receiving
monitoring
by
deactivating
the
FailSafe
mode
in
the
transmitter
and
finishing
the
programming
mode
of
SkyFire
LCU
with
red
flashing
LED.
After
finishing
the
programming
mode,
the
SkyFire
LCU
restarts.
DONE
‐
The
SkyFire
LCU
is
now
fully
programmed
and
can
be
used.
Содержание SkyFire LCU