6. GSC-02A Setting

Initialize your GSC-02A to match to the target stages and host environment (your PC, etc.). The 
initialization  includes  DIP  Switch  settings  and  current  adjustments  (RUN/STOP)  for  each  axis 
motor.

6-1. Set parameters with DIP Switch

Initialize your GSC-02A by setting each switch to ON/OFF as follows:

Parameter Assignment in the DIP Switch:

Table6-1-1: DIP switch setting items

DIP Switch No.

Items

Parameters

1,2

Baud rate

2400 / 4800 / 9600 / 19200

3

Detecting the mechanical origin

MARK method / MINI method

4

Input logic for the limit sensor

Normal open/ Normal close

5

Specify whether to return mechanical origin 
for each axis

First axis only/ Both axis

Switch settings and Corresponding Parameters (Set to ON by turning to the downside)

Table6-1-2: DIP switch setting list

Items

Dip Switch No.

Descriptions

Baud rate

SW No.1

SW No.2

ON

ON

2400 [bps]

OFF

ON

4800 [bps]

ON

OFF

9600 [bps]

OFF

OFF

19200 [bps]

Detecting the

mechanical origin

SW No.3

ON

MARK method*

OFF

MINI method*

Input logic for the

limit sensor

SW No.4

ON

Normal open

OFF

Normal close

Specify whether to

return mechanical

origin for each axis

SW No.5

ON

First axis only

OFF

Both axis

Note)   Shaded areas in the list show our factory settings. Tale care to handle the very small DIP 

Switch so as to avoid giving damage to them during the settings. Use appropriate tools 
such  as  sharp  tweezers  for  setting  switches  on  the  DIP  Switch.  For  our  OSMS  series 
stages, select MINI method and Normal close.

*) For details on the method of return to origin, see page 20.

7

Osaka branch

Содержание GSC-02A

Страница 1: ...User s Manual Intelligent Driver Two Axis Stage Controller GSC 02A User s Manual Intelligent Driver GSC 02A...

Страница 2: ...ct data diagrams charts programs and algorithm please be sure to evaluate all information and products SIGMAKOKI CO LTD assumes no responsibility for any damage liability or other loss resulting from...

Страница 3: ...stem 4 4 Parts of the GSC 02A 5 Chapter 2 Basic Operations 6 5 GSC 02A Connection procedure 6 6 GSC 02A Setting 7 Chapter 3 Using GSC 02A to position Motorized Stages 9 7 Using Computer to position Mo...

Страница 4: ...the manual in the case that you operate the part of the symbol mark on the product This symbol labeled on the portion calls your attention Disclaimer of liability SIGMAKOKI CO LTD does not accept liab...

Страница 5: ...d below Check the package contents using the following checklist Contact your retailer as soon as possible in the event that you should find that any item is missing or damaged You can download sample...

Страница 6: ...T 02 an optional product 3 The GSC 02A System Note that applicable cables and drive current values are depending on the specifications of stages used Check if your controller can adequately control de...

Страница 7: ...axes Earth terminal Should be grounded properly in your environment Power terminal Connect to the power source 24 V 2 A STAGE1 RUN volume Volume control adjusting the RUN current output through the st...

Страница 8: ...GSC 02A The following descriptions premise the RS232C interface Please confirm the power source is turning off Use a genuine cable RS232C STR or 9 pin D SUB straight cable with male female ends using...

Страница 9: ...nly Both axis Switch settings and Corresponding Parameters Set to ON by turning to the downside Table6 1 2 DIP switch setting list Items Dip Switch No Descriptions Baud rate SW No 1 SW No 2 ON ON 2400...

Страница 10: ...50 Driving current settings RUN Factory set to 0 35 A Phase Table6 2 1 Driving current settings Volume No 0 1 2 3 4 5 6 7 8 9 10 RUN current A phase 0 25 0 26 0 3 0 34 0 44 0 53 0 6 0 67 0 75 0 78 0 8...

Страница 11: ...8 bit Stop bit 1 bit Flow control Hardware RTS CTS 7 1 List of Commands The following is a list of available commands Table7 1 1 Command list Command String Details Return to mechanical origin H Dete...

Страница 12: ...input To determine whether or not a command was received normally use the Q command to check status System Type B can select use ACK or not use ACK when send command for computer to controller If sele...

Страница 13: ...n the positive direction and Axis 2 in the negative direction Ex4 H W Detects mechanical origin for Axis 1 in the negative direction and Axis 2 in the negative direction Note If there is no parameter...

Страница 14: ...n the second axis G Drive Note During stage operating status is Busy the command status is NG Note During motor excitation off by C command motorized stages can t move and the command status is NG 4 J...

Страница 15: ...tes and stops Command format L n parameter n 1 or 2 or W 1 first axis 2 second axis W both first axis and second axis Ex1 L 1 First axis decelerates and stops Ex2 L W First and second axis decelerate...

Страница 16: ...0 pps F 1000 pps R 10 ms and second axis S 300 pps F 3000 pps R 20 ms Note During stage operating status is Busy the command status is NG 10 D command Speed settings2 Features The minimum speed S maxi...

Страница 17: ...and Hold second axis motor Note During stage operating status is Busy the command status is NG Note During all of electromagnetic current off by C command motorized stages can t move and the command s...

Страница 18: ...s Ex 001 N Device name Ex N GSC 02A System Type A GSC 02B System Type B DR Direction of travel 0 or 1 Ex DRW 0 0 Ex DR2 0 0 POS 1 NEG LSL Input logic for the limit sensor 0 or 1 Ex LSLW 0 0 Ex LSL2 0...

Страница 19: ...d on again to reflect the system type change settings Note When changing the System Type the settings made in System Type B will be initialized Note During stage operating status is Busy the command s...

Страница 20: ...nput logic of second axis to Normal Open Note During stage operating status is Busy the command status is NG 18 OSL command Detection logic for the ORG sensor Enabled only for System Type B Features S...

Страница 21: ...nsor input logic of first axis to Normal Close and set the NEAR sensor input logic of second axis to Normal Open Note During stage operating status is Busy the command status is NG 20 ORG command Meth...

Страница 22: ...S detection ORG SPEED F CCW Move 1000 pulse CW CCW sensor CCW CW sensor ORG SPEED F CW CW LS detection ORG SPEED S CCW Move 1000 pulse ORG SPEED S CW CW LS detection ORG SPEED F CCW ORG SPEED S CW ORG...

Страница 23: ...is 2 Command format S nd parameter n 1 or 2 or W 1 first axis 2 second axis W both first axis and second axis d 1 or 2 1 Full step 2 Half step If n is set to W m needs to be set for two Ex1 S 12 Set t...

Страница 24: ...or W 1 first axis 2 second axis W both first axis and second axis spds Minimum speed S 1 to 30000 pps spdf Maximum speed F 1 to 30000 pps spdr Acceleration deceleration time R 1 to 1000 ms If n is se...

Страница 25: ...it System Type A Only limit sensor logic can be changed with the settings of switch 4 on the DIP Switch System Type B All sensor logic can be changed by sending a command Method of return to origin MI...

Страница 26: ...de Half step Full step driving Driving RUN current 0 25 A phase to 0 8 A phase Current down function Automatic current down 4 Electrical fast transmit burst immunity EN61000 4 4 2012 Level2 5 Electros...

Страница 27: ...ORG mechanical origin detection 15 24 V sensor power supply 8 24 V sensor power supply Connector Type D sub 15pin female connector mm screw threads 9 2 RS232C connector No Name No Name 1 6 DTR 2 TxD O...

Страница 28: ...GSC 02A User s Manual 10 Exterior Dimensions 60 60 30 20 125 40 180 3 M3 0 5 Depth4 SJT 02 26 Osaka branch...

Страница 29: ......

Страница 30: ...ku Osaka 532 0011 JAPAN 1 19 9 Midori SIGMA KOKI Tokyo Head o ce Sumida ku Tokyo 130 0021 JAPAN Tel 81 6 6307 4835 Fax 81 6 6307 4834 E mail sales osaka sigma koki com 3 17 Hie machi Hakata ku Fukuok...

Отзывы: