23
4 Alarm inputs are available and each alarm is activating to presets, group tours or patterns.
I-1.
ALARM SET
– ALARM NO.
Up to 4 alarms are selectable by using joystick to the right direction when cursor is on ALARM NO.
I-2.
ALARM SET
– ALARM INPUT
Input alarm ways provide two different ways as NC (Normal Close) or NO (Normal Open)
The default setting is OFF
I-3.
ALARM SET
– ALARM ACT
Alarm activates various surveillance modes with Preset number up to 165, Group tour up
to 8, Pattern up to 8. Move joystick to the right or left direction to select any preset
number, group tour no. or pattern no.
I-4.
ALARM SET
– SAVE
After setting the alarm input ways and activation, to save the data, move joystick to the right
direction when the cursor is on SAVE. After saving the data, the cursor moves to Alarm NO.2
automatically to prepare the next alarm.
I-5.
ALARM SET
–EXIT
To escape this page, move joystick to the right direction
* Before activating Alarm, user must set ALARM ENABLE at DOME SET
– ALARM – ENABLE
(Refer to page 15)
ALARM SET
ALARM NO : 01
ALARM INPUT: OFF
ALARM ACT : 001
SAVE
EXIT
DEFAULT SETTING