A. CONNECTION MATHOD
A-1
1.
Loose the screws on the domes cover and remove it from the base.
(
Screws won’t be removed)
2. Loose the screws which connect mount cover and Main base and separate dome cover from the
main base. (
Screws won’t be removed)
3. Connect power (
DC12V 1.5 A
) to Power and GND.
4. Connect video to Video and GND.
5. Connect communication cable to RS-485 connectors.
6. Connect alarm cable to GND like 1 and GND, 2 and GND, 3 and GND, 4 and GND.
(You can use both N.O / N.C methods.)
D
on’t screw too tightly. It can be the cause of defect.
INSTALLATION