OPTIMUM
M A S C H I N E N - G E R M A N Y
Notes, messages and error messages
Version 1.1.6 dated 2014-10-16
Page 87
Original operating instructions
F150
GB
700028
Tool data error
possible rem-
edy
•
Check tool table!
700030
Machine control panel error (MCP)
possible rem-
edy
Check type / MD / connection.
700031
Magazine in / out error.
700032
Waiting for SINAMICS ready. . .
700033
Operator door safety check, open door and close it again.
Cause and
solution
Safety door needs test, open then close it again.
•
Press the push button "door open - close"
•
Open the door and close the door again completely.
•
Press after closing the door the push button "RESET.
"Switching on the CNC machine“ on page 73
700040
Waiting for tool clamped.
700041
Waiting for tool unclamped.
700044
Tool probe Low battery
700046
Tool probe error
700048
Coolant motor overloaded
Possible cause
and remedy
•
Motor protection switch of the coolant pump is faulty.
•
Motor protection switch setting faulty.
•
Coolant pump is sucking air.
•
Shut-off cock is closed.
•
Pump or drive motor defective.
Possible cause
and remedy
•
Contactor of the coolant motor signals an incorrect switch status.
700050
Coolant level low.
Possible cause
and remedy
•
Fill up coolant
•
Float switch in the central oil lubrication
700051
CTS coolant motor overloaded.
700052
CTS recycle motor overloaded.
700053
CTS sub-tank level low, no coolant suction.
700055
CTS inlet filter clogged.
700056
CTS sub-tank level high.
700060
Spindle oil cooler alarm !
700064
Waiting for tool change . . .
700075
Waiting for gear changing. . .
700080
Asup1 initialise error, check PLCASUP1.SPF
700081
Asup2 initialise error, check PLCASUP2.SPF
700082
Asup1 execution error.
Number