Short description of main window controls (see Figure 8 and Figure
):
1.
Top window selection:
-
Find Probe
–
allows calibration of probe tip position in respect to the camera image.
-
Wellplates
–
allows moving to selected well in the plate.
-
Calibration
–
calibration of the probe.
-
Camera
–
camera settings and automatic image saving options.
-
Options
–
settings for Find Surface and fitting of data.
-
Config. exp.
–
set up indentation protocol and other steps.
-
Maintenance
–
additional settings.
2.
Probe stage controls:
-
Single arrow
–
controls the step size of the probe stage and allows to move it up and down.
-
Double arrow (Z up)
–
moves up the probe stage to 0 position.
-
Incr. (µm)
–
step size.
-
Set transit height
–
saves current probe stage position Z to “Transit(
µ
m)”.
-
Go to transit height
–
moves down the probe stage to the selected height in “Transit(
µ
m)”.
3.
Stage location:
-
X(µm)
–
X stage coordinate.
-
Y(µm)
–
Y stage coordinate.
-
Z(µm)
–
probe stage coordinate.
-
O(µm)
–
objective stage coordinate.
-
“plate 1, A4”
–
current probe position within wellplate.
-
Piezo (µm)
–
current position of the piezo together with the bar.
4.
Microscopy:
-
Bright field
–
turns on bright-field LED.
-
Phase one
–
turns on phase-contrast LED suited for x20 objective.
-
Phase two
–
turns on phase-contrast LED suited for x40 objective.
-
LED intensity
–
adjusts LED intensity.
5.
Temperature control:
-
ON/OFF
–
turn on and off the temperature control.
-
Set point (
°C
)
–
set temperature from 15 to 50°C.
-
Air temp. (
°C
)
–
air temperature measured at the sensor (inside the frame).
-
Humidity (%)
–
relative humidity.
6.
Objective control:
-
Auto cam adjust
–
automatically adjusts camera settings in “Camera” based on the
current
image.
-
Single arrow
–
controls the step size of the objective stage and allows to move it up and down.
-
Double arrow (objective down)
–
moves down the objective stage to 0 position.
-
Incr. (µm)
–
step size.
-
Set focal plane
–
saves current
objective stage position Z to “Focal plane(
µ
m)”.
-
Go to focal plane
–
moves up the objective stage to the selected height in “Focal plane (
µ
m)”.
7.
Run experiment:
-
Save image
–
saves the current camera image.
-
Reset
–
resets all the hardware.
-
Home stages
–
moves all stages to the initial position.