OPTICON
Software Guide
MDL-1000/2000
46
Name
Parameter
NO.(Hex)
Value
(Hex)
Function
Default
Codabar CLSI Editing
36 00
01
Eliminate Start/Stop Character and
Insert space (20H) after the first, fifth
and tenth digits.
*Eliminate Start/Stop Characters only
when it is 14-digit bar code.
○
No Transmit
Codabar Start/Stop
Character
37 00
01
Disable
Enable
○
Decoding of
MSI/Plessey
0B 00
01
Disable
Enable
○
Fix Length of
MSI/Plessey
1E
(
L1
)
1F
(
L2
)
Value Refer to “5-2-1. Digit Number Setting”
6-55
MSI/Plessey Check
Digits
32 00
01
One Check Digit
Two Check Digits
○
Transmit MSI Check
Digits
2E 00
01
Disable
Enable
○
MSI Check Digit
Algorithm
33 00
01
Mod10/Mod11
Mod10/Mod10
*Only valid when the Check Digits are
in 2 digit numbers.
○
Decode of RSS-14
F0 52
00
01
Disable
Enable
○
Decode of
RSS-Limited
F0 53
00
01
Disable
Enable
○
Decode of
RSS-Expand
F0 54
00
01
Disable
Enable
○
Transmit Code ID
2D 00
01
02
Disable
AIM Specification
Symbol Technologies Specification
○
Prefix/Suffix Value
69 (P)
68
(
S1
)
6A (S2)
Value P:
prefix
S1: suffix1
S2: suffix2
Value is specified in ASCII codes
NULL
LF
CR
Data Transmission
Format
EB 00
01
02
03
04
05
06
07
<data> Data Only
<data><suffix1>
<data><suffix2>
<data><suffix1><suffix2>
<prefix><data>
<prefix><data><suffix1>
<prefix><data><suffix2>
<prefix><data><suffix1><suffix2>
○