5
.
PARAMETER
5-1
Table of Parameters
The following is list of parameters send out in PARM_DATA
Name
Parameter
NO.(Hex)
Value
(Hex)
Function Default
BEEP Volume
8C 00
03
09
Low
Mid.
High
○
BEEP Frequency
91 02
01
00
Low
Mid.
High
○
BEEP Frequency
(Value Setting)
F0
91 Value Setting Range: 1220Hz-3770Hz
Step 10Hz
2500Hz
Decoding Time
88
Value Setting Range: 0.5sec-9.9sec
Step 0.1sec
3.0sec
Aiming Delay
ED
Value Setting Range: 0.0sec-9.9sec
Step 0.1sec
0.0sec
Scan Angle
BF 05
06
Narrow
Wide
○
Power Mode
80 00
01
Continuous
Low Power
○
Trigger Mode
8A
00
02
04
07
08
09
Level
Pulse
Continuous
Reserve
Host
Decode while trigger signal is active
○
Duplication Buffer
Time-out
89 Value
Setting Range: 0.0sec
~
9.9sec
Step 0.1sec
1.0sec
Good Decode Beep
38
01
00
Enable
Disable
○
“NO READ”
message
5E 01
00
Enable
Disable
○
Check Level
(Linear Code applicable
to Codabar/MSI/D.2of5
and i.2of5
)
4E 01
02
03
04
Level 1
Level 2 *Refer to “5-2-5. Linear Code”
Level 3
for the details of each level.
Level 4
○
Verification Method
43
01
00
Sequential
Verification based on results of
bi-directional scanning.
Interval
Verification based on the result of
scanning in one direction
○