OPTICON
Software Guide
MDL-1000/2000
52
5-2-5.
UPC/EAN Consistency Verification
・
Level0
(Default Setting Value)
There will be no consistency verification before transmission.
・
Level1
UPC, EAN, and JAN bar codes must be successfully read twice before transmission.
(1 consistency checkup)
・
Level2
UPC, EAN, and JAN bar codes must be successfully read three times before transmission.
(2 consistency checkups)
・
Level3
UPC, EAN, and JAN bar codes must be successfully read four times before transmission.
(3 consistency checkups)