- 4 -
- 5 -
ENGLISH
FRANÇAIS
DEUTSCH
IT
ALIANO
ESP
AÑOL
a
d
c
b
a
d
c
b
5
Install the cable gland.
6
Install the main unit and fix it to the mounting bracket.
Adjust the angle so that the inclination in the vertical
direction becomes parallel to the ground.
7
See section “4-” and connect the wires to the terminal
block.
Cautions>>
When the indicators (A, A2, B, B2, Status and Power)
light after the power turns on, this signifies that the system
is warming up. Wait for approximately 30 seconds until the
indicators go out.
8
See Chapters 5, 6 and 7, make various settings and confirm
that the equipment operates correctly.
9
The installation work is complete when the various settings
and operational check are finished. Mount the cover.
3-2 INSTALLING TO CEILING PLANE
AND ANGLE ADJUSTMENT
When you have selected the Vertical Detection Area for detection
purposes, install the product to the ceiling plane.
Implement steps
and
2
in “3-” to remove the cover and
mounting bracket.
2
Attach the paper template (an accessory) to the ceiling
plane and drill 4 mounting holes in it. Drill 2 wiring holes as
required.
Insert the anchor bolt (an accessory) into the board
mounting holes.
3
Fix the mounting bracket to the ceiling plane.
4
Install the main unit and fix it to the mounting bracket. Adjust
the angle so that the inclination in the vertical direction
becomes parallel to the ground.
5
Take steps
6
through
9
in “3-” to do wiring, check the
setup and operation, and then install the cover.
1
Install the main unit by moving it over the
stopper while opening the bottom of the
mounting bracket slightly outward.
Ensure that any unused
wiring holes are covered
securely with a wiring
hole cap.
Cable gland
Main unit fall-
protection stopper
3
Tighten 4 lock screws.
Angle adjustment
screws a and b
Main unit mounting
screws c and d
(Washer without
rubber)
2
Insert the top portion
When tightening screws a and b,
adjust the angle referencing the
slot.
2
Tighten 2 lock screws.
1
Install the cover.
Wiring hole
Peel off the paper template from the portion indicated
with the dotted line when using its inner portion alone.
Mounting hole in 4 locations
Diameter 6 mm (0.24 inches)
Depth
60 mm (2.36 inches)
Tighten 4 lock screws
for the mounting
bracket (accessories).
They are not
used
Main unit fall-
protection stopper
1
Install the main unit by moving it over the
stopper while opening the bottom of the
mounting bracket slightly outward.
2
Insert the top portion.
3
Tighten 4 lock screws.
(Washer without
rubber)
(Washer with rubber)
Angle adjustment
screws a and b
When tightening screws a and b,
adjust the angle along the slot.
5° 5°
5°
5°
(Washer with rubber)
Main unit mounting
screws c and d