background image

- 0 -

-  -

Auto

P
P2

2

3

Set

A2

Power

A B B2

Status

REDWAVE

REDWAVE

MICROWAVE

REDWAVE

ALARM OUTPUT

CELL BATTERY
POWER

SUPPLY

FROM

SENSOR

POWER OFF

REDWAVE

PIR NEAR

REDWAVE

PIR FAR

MEGARED

FAR

MEGARED

NEAR

REDWALL

REDWIDE

WALKTESTER

REDWALL

REDWIDE

MEGARED

CONNECTION

SELECT

SWITCH

MODE

SELECT

SWITCH

POWER

SELECT

SWITCH

OPM-WT

Area B

Area A

0

8

6

24

4

2

20

28

0

4

8

2

6

20

24

28

7

F

SETTING VERTICAL DETECTION AREA

6

-Setting P2 (Auto Tracing)

H Manual H Auto

H2 Manual H2 Auto

V Auto

Sequence of 

operation

Status 

indicator

Time

Action of REDSCAN/

Response of Walk Tester

Hold down the 

detection area setting 

button for  second.

Flashing 

starts

For 

 second

Pitch of Walk Tester 

sound changes for 

2 seconds

2

Evacuation from 

the area

Flashing

(*2)

For 

5 seconds

Fast flashing 

(*3)

For 

0 seconds

Scan of the detection 

area is executed

3

Walking along the 

boundary of the area

(*)

Flash

(*4)

For 

5 minutes

Tracing started

Pitch of the Walk Tester 

sound changes in 

3-second cycles

(Last 

30 seconds)

Pitch of the Walk Tester 

sound changes in 

-second cycles

ON

For 

5 seconds

Tracing is completed and 

the data are saved

Flashing

For 

3 seconds

OFF

Security protection of the 

detection area is started

*:   The tracing is automatically ended after 5 minutes. When 

movement of the target object along the area boundary has 

finished before this time, you can terminate the tracing without 

waiting for 5 minutes by holding down the detection area 

setting button for 3 seconds.

*2:  Flashes once a second

*3:  Flashes twice a second

*4:   A  flashing  sequence  of  flashing  twice  a  second  and  not 

flashing for a second is repeated

Cautions >>

Do not enter the area while the area scan is being carried 

out. An unwanted object in the area interferes with the 

correct scanning of the target area.

Note >>

Any area left untraced will revert to the Auto learning area 

settings.

6- SELECTOR SWITCH OPERATION

-Detection method selection

H Manual H Auto

H2 Manual H2 Auto

V Auto

Select the desired method using the detection 

method selector switch.

Func.

H

V

H2

SELECTOR

POSITION

FUNCTION

H

H2

V

Selects the vertical detection area.

-Selection of the area setting method

H Manual H Auto

H2 Manual H2 Auto

V Auto

Select the desired method using the mode 

selector switch.

Mode

M

A

SELECTOR

POSITION

FUNCTION

M

NOT APPLICABLE

A

Selects the Auto setting.

-Selecting the Auto mode

H Manual H Auto

H2 Manual H2 Auto

V Auto

Select it using the Auto mode selector switch.

Auto

P
P2

SELECTOR

POSITION

FUNCTION

P

Fixes the detection area.

P2

Periodically refreshes the detection 

area.

-Setting the detection sensitivity

H Manual H Auto

H2 Manual H2 Auto

V Auto

Set the detection sensitivity using the Size selector switch and 

Sens. selector switch. You can set the detection sensitivity in the 

vertical area with the size of the target object and the time it takes 

to traverse the detection area.

H

M

L

S

M

L

Size

Sens.

SELECTOR 

POSITION

FUNCTION

S

Approx. 300 mm 

( ft.) or above

This switch 

specifies the 

height from 

offset position 

of the target 

object to be 

detected.

M

Approx. 500 mm 

(.6 ft.) or above

L

Approx. 000 mm 

(3.3 ft.) or above

H

00 ms or longer. This 

setting is recommended 

when the target object 

can run through the 

detection area.

This switch 

specifies 

the duration 

during which 

the target 

object stays in 

the detection 

area.

M

50 ms or longer

L

200 ms or longer. This 

setting is recommended 

when detecting large 

objects such as a car.

 

6-2 SETTING DETECTION AREA IN 

VERTICAL DETECTION AREA

H Manual H Auto

H2 Manual H2 Auto

V Auto

Set a fan-like detection area using the rough alignment rotary 

switch and fine alignment potentiometer.

-Rough alignment rotary switch

It can specify the radius in the range of 0 to 30 m in 2 m steps.

Setting the rough alignment rotary switch to 0 m deletes the area.

SELECTOR 

POSITION (m)

[ft.]

0

0

4

3

8

26

2

39

6

52

20

65

24

79

28

92

Auto P (Auto Learning)

Manual Mode

Area

B2

Area

B

Area

A

Area

A2

: Detection area

Installation 

height

Ground surface

5 m

7 m

30 m

4 m

Содержание RLS-3060

Страница 1: ...duct is wet with rain etc It may cause electric shock Never attempt to disassemble or repair the product It may cause fire or damage to the devices Do not exceed the voltage or current rating specifie...

Страница 2: ...period 36 s Standard IEC60825 1 Class 1 of the Laser Safety Standard means that the safety of laser products belonging to this class is warranted under normal operating conditions reasonably predictab...

Страница 3: ...epending on which detection method of either H1 H2 or Vertical detection Area is selected Horizontal Detection Area 1 Horizontal Detection Area 2 Manual In this mode set up a detection area by specify...

Страница 4: ...the angle so that the inclination in the horizontal plane becomes parallel to the ground Cautions When installing the product to the wall fix the mounting bracket parallel to the ground If the mounti...

Страница 5: ...nit and fix it to the mounting bracket Adjust the angle so that the inclination in the vertical direction becomes parallel to the ground 5 Take steps 6 through 9 in 3 1 to do wiring check the setup an...

Страница 6: ...g the product at an angle to a wall attach the paper template attached to the main unit to the wall and drill 4 mounting holes in it in the same way as described in 3 1 3 For the ceiling plane follow...

Страница 7: ...Upon detecting an intruder this product outputs the alarm specific to the area Area A1 Area A2 Area B1 or Area B2 where the intrusion happened When combined with an area monitoring system using a PTZ...

Страница 8: ...ed Area A1 alarm output B1 Red Area B1 alarm output B2 Red Area B2 alarm output Status Yellow Lit during auto setup of the unit Turned off during normal operation Power Green Lit when power is turned...

Страница 9: ...20 65 24 79 28 92 Fine alignment potentiometer This potentiometer can fine tune the value set with the rough alignment rotary switch by 1 m within the range of 0 m minimum and 30 m maximum Setting don...

Страница 10: ...d selection H1 Manual H1 Auto H2 Manual H2 Auto V Auto Select the desired method using the detection method selector switch Func H V H2 SELECTOR POSITION FUNCTION H1 H2 V Selects the vertical detectio...

Страница 11: ...al H1 Auto H2 Manual H2 Auto V Auto Ensure that the detection area has been correctly set referencing the red indicator and changes in the pitch of Walk Tester sound When a detection area has not been...

Страница 12: ...wer Green LED Area alarm output N O 28V DC 0 2A 4outputs Master alarm output Form C 28V DC 0 2A max Trouble output Form C 28V DC 0 2A max Tamper output N C 28V DC 0 1A max Environmental disqualificati...

Отзывы: