background image

- 0 -

-  -

ENGLISH

FRANÇAIS

DEUTSCH

IT

ALIANO

ESP
AÑOL

Fine

adj.

Area A

-  +

-  +

Area B

Range

0

8

6

24

4

2

20

28

0

4

8

2

6

20

24

28

7

F

Offset

-   0

2

Set

A2

Power

A B B2

Status

REDWAVE

REDWAVE

MICROWAVE

REDWAVE

ALARM OUTPUT

CELL BATTERY
POWER

SUPPLY

FROM

SENSOR

POWER OFF

REDWAVE

PIR NEAR

REDWAVE

PIR FAR

MEGARED

FAR

MEGARED

NEAR

REDWALL

REDWIDE

WALKTESTER

REDWALL

REDWIDE

MEGARED

CONNECTION

SELECT

SWITCH

MODE

SELECT

SWITCH

POWER

SELECT

SWITCH

OPM-WT

Set

A2

Power

A B B2

Status

REDWAVE

REDWAVE

MICROWAVE

REDWAVE

ALARM OUTPUT

CELL BATTERY
POWER

SUPPLY

FROM

SENSOR

POWER OFF

REDWAVE

PIR NEAR

REDWAVE

PIR FAR

MEGARED

FAR

MEGARED

NEAR

REDWALL

REDWIDE

WALKTESTER

REDWALL

REDWIDE

MEGARED

CONNECTION

SELECT

SWITCH

MODE

SELECT

SWITCH

POWER

SELECT

SWITCH

OPM-WT

-Fine alignment potentiometer

This potentiometer can fine tune the value set with the rough 

alignment rotary switch by +/-  m. within the range of 0 m 

minimum and 30 m maximum.

Setting carried out in 

rough alignment

Range available for fine alignment

When 0 m is set

0 to + m (From - to 0 m on the scale 

is not usable)

When 2 to 28 m is set

± m

When 30 m is set

- to 0 m (From 0 to + m on the scale 

is not usable)

-Offset adjustment

You can reduce a set detection area using the offset 

potentiometer. Use this adjusting function when windblown 

grasses or tree branches interfere with the currently set detection 

area.

You can adjust the dead zone from the ground in the range of 0 

to - m.

6-3 AUTO SETTING OF VERTICAL DETECTION AREA

H Manual H Auto

H2 Manual H2 Auto

V Auto

Sequence of 

operation

Status 

indicator

Time

Action of REDSCAN/

Response of Walk Tester

Hold down the 

detection area setting 

button for  second.

Flashing 

starts

For 

 second

Pitch of Walk Tester 

sound changes for 

2 seconds

2

Evacuation from 

the area

Flashing 

(*)

For 

5 seconds

Fast 

flashing (*2)

For 

0 seconds

Scan of the detection 

area is executed

ON

For 

5 seconds

Scan of the detection 

area is completed and 

the data are saved

Flashing

For 

3 seconds

OFF

Security protection of 

the detection area is 

started

*:  Flashes once a second

*2:  Flashes twice a second

Cautions >>

Do not enter the area while the area scan is being carried 

out. An unwanted object in the area interferes with the 

correct scanning of the target area.

7- WALK TEST

H Manual H Auto

H2 Manual H2 Auto

V Auto

Ensure that the detection area has been correctly set referencing 

the red indicator and changes in the pitch of Walk Tester sound.

-When a detection area has not been correctly set

 

  Before pressing the detection area setting button, ensure 

that the detection method switch and the detection mode 

switch are set to the correct position, respectively.

 

2

  Set the detection again with reference to “5-4” for the 

horizontal detection area and “6-3” for the vertical detection 

area.

7-2 CHANGING THE SETTINGS DURING SECURITY PROTECTION

H Manual H Auto

H2 Manual H2 Auto

V Auto

You can change the following settings as required during the 

security protection.

It is not necessary to press the detection area setting button after 

conducting a change.

SELECTOR 

NAME

Manual (M)

Auto (A) <P/P2>

Mode selector

Object size

Object movement

Rough alignment

Fine alignment

Offset

If you shift the mode selector switch from Manual (M) to Auto (A), 

the area that has been specified previously in Auto (A) is selected 

as the detection area. When the area is not set in Auto, set it with 

reference to the procedure described in “5-4” or “6-3.”
Summary of detection area switch settings

Function

AUTO MODE

(Press Detection area setting button to initiate)

MANUAL MODE

P

P2

H

Automatically learns 

the detection area 

within  m x area set by 

Rough alignment rotary 

switches and Fine adj. 

potentiometers

N/A

Detection area 

is  m x Area 

set by Rough 

alignment 

rotary switches 

and Fine adj. 

potentiometers

H2

Automatically learns 

the detection area 

within the area set by 

Rough alignment rotary 

switches and Fine adj. 

potentiometers

Automatically learns the 

detection area by tracing 

a person walking a 

boundary within the area 

set by Rough alignment 

rotary switches and Fine 

adj. potentiometers

Detection area is 

the Area set by 

Rough alignment 

rotary switches 

and Fine adj. 

potentiometers

V

Automatically learns 

the detection area 

within the area set by 

Rough alignment rotary 

switches and Fine adj. 

potentiometers

Automatically updates the 

detection area every hour 

within the area set by 

Rough alignment rotary 

switches and Fine adj. 

potentiometers

N/A

AREA CHECKUPS

7

Offset

Ceiling

Ground 

surface

Installation 

height

Area

B2

Area

B

Area

A

Area

A2

Installation 

height

Ground surface

Manual

Auto P (Fix)

Area A

Area B

Area

A

Area

B

Area

B2

Area

A2

Ensure that the action of walking into an area causes 

the corresponding red indicator to turn on.

30 m

Содержание RLS-3060

Страница 1: ...duct is wet with rain etc It may cause electric shock Never attempt to disassemble or repair the product It may cause fire or damage to the devices Do not exceed the voltage or current rating specifie...

Страница 2: ...period 36 s Standard IEC60825 1 Class 1 of the Laser Safety Standard means that the safety of laser products belonging to this class is warranted under normal operating conditions reasonably predictab...

Страница 3: ...epending on which detection method of either H1 H2 or Vertical detection Area is selected Horizontal Detection Area 1 Horizontal Detection Area 2 Manual In this mode set up a detection area by specify...

Страница 4: ...the angle so that the inclination in the horizontal plane becomes parallel to the ground Cautions When installing the product to the wall fix the mounting bracket parallel to the ground If the mounti...

Страница 5: ...nit and fix it to the mounting bracket Adjust the angle so that the inclination in the vertical direction becomes parallel to the ground 5 Take steps 6 through 9 in 3 1 to do wiring check the setup an...

Страница 6: ...g the product at an angle to a wall attach the paper template attached to the main unit to the wall and drill 4 mounting holes in it in the same way as described in 3 1 3 For the ceiling plane follow...

Страница 7: ...Upon detecting an intruder this product outputs the alarm specific to the area Area A1 Area A2 Area B1 or Area B2 where the intrusion happened When combined with an area monitoring system using a PTZ...

Страница 8: ...ed Area A1 alarm output B1 Red Area B1 alarm output B2 Red Area B2 alarm output Status Yellow Lit during auto setup of the unit Turned off during normal operation Power Green Lit when power is turned...

Страница 9: ...20 65 24 79 28 92 Fine alignment potentiometer This potentiometer can fine tune the value set with the rough alignment rotary switch by 1 m within the range of 0 m minimum and 30 m maximum Setting don...

Страница 10: ...d selection H1 Manual H1 Auto H2 Manual H2 Auto V Auto Select the desired method using the detection method selector switch Func H V H2 SELECTOR POSITION FUNCTION H1 H2 V Selects the vertical detectio...

Страница 11: ...al H1 Auto H2 Manual H2 Auto V Auto Ensure that the detection area has been correctly set referencing the red indicator and changes in the pitch of Walk Tester sound When a detection area has not been...

Страница 12: ...wer Green LED Area alarm output N O 28V DC 0 2A 4outputs Master alarm output Form C 28V DC 0 2A max Trouble output Form C 28V DC 0 2A max Tamper output N C 28V DC 0 1A max Environmental disqualificati...

Отзывы: