Operator Manual
OPEX Corporation
Feed Entry RX Present
Sensor Blocked
The Feed Entry RX Present Sensor is blocked.
Fan Failure Detected
A fan has stopped functioning.
Roller Bed Motor Fault
Detected
This event can occur during a job activation of
the roller bed motor and a stall, over-current,
under-current, thermal warning or thermal
shutdown is detected by the stepper controller.
Feeder Motor Fault
Detected
This event can occur during a job activation of
the feeder motor and a stall, over-current,
under-current, thermal warning or thermal
shutdown is detected by the stepper controller.
Scan Bed Motor Fault
Detected
This event can occur during a job activation of
the scan bed motor and a stall, over-current,
under-current, thermal warning or thermal
shutdown is detected by the stepper controller.
Stacker Motor Fault
Detected
This event can occur during a job activation of
the stacker motor and a stall, over-current,
under-current, thermal warning or thermal
shutdown is detected by the stepper controller.
ID1 Assist Verify Jammed
This event can occur during a run when the ID1
ASSIST VERIFY sensor is blocked longer than
the configurable amount of time has allowed.
The
id assist sensor jammed time (5000)
machine parameter configures this timeout. The
default is 5000 milliseconds or 5 seconds.
Servo Fuse 1 Fault Detected
This event can occur during a run when the fuse
for the servo motor, which controls the upstream
or right-hand pre-feed arm, is detected to be
open or blown.
Servo Fuse 2 Fault Detected
This event can occur during a run when the fuse
for the servo motor, which controls the
downstream or left-hand pre-feed arm, is
detected to be open or blown.
Table 6-5: Reasons for jams (continued)
Содержание Falcon+
Страница 10: ...10 Table of Contents Falcon Operator Manual OPEX Corporation This page is intentionally blank...
Страница 16: ...16 Introduction Falcon Operator Manual OPEX Corporation This page is intentionally blank...
Страница 26: ...26 Overview Falcon Operator Manual OPEX Corporation This page is intentionally blank...
Страница 64: ...64 Operation Falcon Operator Manual OPEX Corporation This page is intentionally blank...
Страница 132: ...OPEX Corporation 305 Commerce Drive Moorestown NJ 08057 4234 USA http www opex com...