background image

INSTALLATION

Check   the   bar   is   correctly   installed   and   the

holes  for   the  handle  frame   and  fixing  screws

are present on the door. 

Insert   the  handle  as  shown  in  the  figure   and

rotate it in the desired direction.

NB :   for   versions  40620  and  40621  this
operation must be performed when power is
ON;   for   versions  40820  and  40821  when
power is OFF.

Fix   the   handle   with   the   appropriate   supplied

screw and split washer (Grower).

Before   completing   the   installation,   it   is

necessary to select the rotation of the spindle

drive using the appropriate selector on the back

of   the   handle.   It   can   be   of   45°   or   60°,

depending   on   the   bar   to   fit   with   the   electric

handle. 

To change the selection, use a flat screwdriver,

press and rotate the spindle selector until the

the cut lines up with the desirered degrees (see

figure).   Release   the   spindle   selector   in   the

desidered position.  

                

 

 60° Rotation

 45° Rotation

Содержание 40620

Страница 1: ...ELECTRIC HANDLE OUVERTURE EXIT ...

Страница 2: ...ustable from 0 to 60 seconds NO Adjustable from 0 to 60 seconds EXTERNAL SIGNALING OPEN COLLECTOR NO YES NO YES WHITE BLUE LOWER LIGHTING NO YES NO YES OPEN RELEASE LEVER Both electrical and mechanical Both electrical and mechanical Both electrical and mechanical Both electrical and mechanical The electric handle can be fitted with rim type exit panic devices with visible latch The coupling is pos...

Страница 3: ...OFF Fix the handle with the appropriate supplied screw and split washer Grower Before completing the installation it is necessary to select the rotation of the spindle drive using the appropriate selector on the back of the handle It can be of 45 or 60 depending on the bar to fit with the electric handle To change the selection use a flat screwdriver press and rotate the spindle selector until the...

Страница 4: ...ect the open release lever use the key manually Fix the back plate with the appropriate screws and make sure the fixing bushes are in the correct position in front of the fixing holes on the bar If one of the fixing bushes is placed to the cylinder height tighten the supplied nylons gauge in the back part of the bush see figure Reduce the spindle and the fixing screws as per the indications suppli...

Страница 5: ...andle is disabled in neutral the green LED is off Power supply enables the door opening and green LED turns on as long as power is ON Attention time delay has to be set at 0 seconds for items code 40621 and 40821 It is possible to use both the lead cover and the pressure contacts Activation with dry contact with time delay 40621 40821 series When the electric handle is disabled in neutral the red ...

Страница 6: ...duration of the electrical pulse only Time delay configuration from 5 to 60 seconds 1 Connect the N O programming switch not included to the blue wire and to the green wire of the ground signals GND 2 Connect the handle to the power supply grey and white wires 3 Plate has a red LED light Press the programming switch until the LED becomes blue Keep the switch pressed and the LED double flashes each...

Страница 7: ... Connect the handle to the power supply keeping the switch pressed 4 Blue LED light will flash twice and it will then become red Releasing the programming switch LED will flash twice confirming the white blue lower lighting deactivation White blue LED s activation 1 Connect the N O programming switch not included to the blue and to the green wire of the ground singals GND 2 Press the programming s...

Страница 8: ...cking screw Pull the cylinder out Move the grub screw from the old to the new cylinder Insert the cylinder back again Tighten the cylinder locking screws The electric handle is suitable for a Euro profile half cylinder Cylinder lenght 40mm 30 10 ...

Страница 9: ...INSTALLATION EXAMPLES Electric handle with Push Bar Electric handle with Touch Bar ...

Страница 10: ...supply 230 Vac In the 406 version use a N C switch WHITE POWER SUPPLY 12 24 Vdc GREY POWER SUPPLY AC power supply with direct electricity activation for items 40620 40621 40820 40821 Transformer 230 Vac In the 406 version use a N C switch WHITE POWER SUPPLY 12 24 Vac GREY POWER SUPPLY Bring timing to 0 seconds ...

Страница 11: ...D OPENING GREEN GND NO POWER SUPPLY LIGHT BLUE PROGRAMMING POSITIVE POWER SUPPLY ORANGE OPEN COLLECTOR 12 24 Vdc MAX 30 mA AC power supply and opening by contact for items 40621 40821 Transformer 230 Vac WHITE POWER SUPPLY 12 24 Vac GREY POWER SUPPLY RED OPENING GREEN GND NO POWER SUPPLY LIGHT BLUE PROGRAMMING ORANGE OPEN COLLECTOR ...

Страница 12: ...UPPLY 12 24 Vdc GREY POWER SUPPLY RED OPENING GREEN GND LIGHT BLUE PROGRAMMING ORANGE OPEN COLLECTOR COM N O RELAY MODULE ITEM 05258 to order separately 12 Vac from INTERCOM OPERA s r l Tel 059 451708 www opera italy com info opera access it n 1506 1926 Rev 0 del 09 06 15 ...

Отзывы: