TIME DELAY CONFIGURATION
(Only for 40621 – 40821 versions)
The electric handle has a time delay system inside which enables to keep the handle
enabled for the time selected by the user.
Time delay configuration at 0 seconds
1. Connect the N.O. programming switch (not included) to the blue wire and to the
green wire of the ground signals.
2. Connect the handle to the power supply (grey and white wires).
3. Plate has a red LED light. Press the programming switch until the LED becomes
blue. Release the programming switch immediately. LED turns on for about one
second to confirm programming. Electric handle remains enabled for the duration
of the electrical pulse only.
Time delay configuration from 5 to 60 seconds
1. Connect the N.O. programming switch (not included) to the blue wire and to the
green wire of the ground signals (GND).
2. Connect the handle to the power supply (grey and white wires).
3. Plate has a red LED light. Press the programming switch until the LED becomes
blue. Keep the switch pressed and the LED double flashes, each flesh
corresponding to 5 seconds. Once the desired timing is achieved, release the
programming switch. LED confirms set timing flashing. Electric handle remains
enabled for the selected time or until the first activation.
ELECTRIC HOLD OPEN DEVICE
To keep the door enabled for a time set by the user, it is necessary to install a switch
in parallel with the opening switch. It will keep the door open until its disconnection.