You have to setup the initial torch height manually when start
arc.
Pierce time setup
The unit of the pierce time is 0.1s (second).
The procedure of the pierce time setup is the same as
above.
Caution: if the pierce time is setup to zero, the controller
will not execute pierce procedure. The CNC controller should
take the responsibility of pierce procedure control.
IHS Test
Press the MENU key once while standby, the controller will
enter into parameter setup interface, then press UP or DOWN
arrow key to select menu items, press the ENTR (enter) key to
enter into IHS test interface when it displays Ihs_Test
information. Now the controller will ask you to press the ENTR
key again to confirm and start the IHS test procedure. Now
you can press the MENU key to exit or the ENTR key to start
the IHS test procedure, you can also press the UP or DOWN
key to enter into IHS_TIME setup procedure to modify the IHS