Arc voltage setup
Press the MENU key once while standby, the controller will
enter into parameter setup interface, then press UP or DOWN
arrow key to select menu items, press the ENTR (enter) key to
setup working arc voltage when it displays Arc_Volt
information. Now the current arc voltage value will be
displayed on the LCD display and the cursor blinks, after that,
press the UP or DOWN arrow key to increase or decrease the
value of working arc voltage. Holding the UP or DOWN key for
about 2 seconds to increase or decrease the value
automatically and faster. Press ENTR key to confirm and exit
to menu item select interface. After all working parameters
have been setup properly, press the MENU key to return to
standby status while menu item select interface.
IHS time setup
The unit of the initial height setup (IHS) time is 10ms
(millisecond).
The procedure of the IHS time setup is the same as above.
Caution: if the IHS time is setup to zero, the controller will not
execute initial height setup procedure and will start arc directly.