Press the MENU key once while standby, the controller will
enter into parameter setup interface, then press the UP and
DOWN arrow key at the same time for about 3 seconds, then
release the key, the controller will enter into inner parameters
setup interface.
Press UP or DOWN key to select the inner parameter
which you want to modify, press ENTR key once to edit
current parameter, and then press the UP or DOWN arrow key
to modify current parameter value, press ENTR key again to
return. Press the MENU key to exit to standby status after all
inner parameters have been setup properly.
MAX_PWM
:
The maximum PWM value of the lifting motor.
This parameter defines the maximum speed of torch
lifting motor.
Range:60-120
,
default
:
120.
MIN_PWM
:
The minimum PWM value of the lifting motor.
This parameter defines the minimum speed of torch
lifting motor.
Range:10-120
,
default
:
30.
IhsUPPWM: The IHS upward PWM value of the lifting