S P E C I A L F U N C T I O N S
100 / 192
XS20000_31_manual_ger_eng_it_V1.1.2.doc
R. Kistler
5.1.2
Commissioning redundant/parallel operation
NOTE
ECO mode is not available, please disable (see
Settings
menu
)
Additional settings must not be made
This chapter discusses the the main features of the parallel
operation and additionally refers to the
Commissioning
section
1. Connect the load (consumers) to the UPS systems without
switching on the load.
2. If there is a maintenance switch installed, switch this to UPS
mode now.
4. Switch the power supply on. Switch the input switches MAIN 1
and MAIN 2 on the rear side of each of the UPS systems to
the "ON" position.
The LCD display on the front covers of the UPS systems lights
up and displays the ONLINE logo.
3. Check whether the UPS systems are in the bypass mode
(see
Operating states
).
4. Press the
button on one of the UPS systems for at least
one second. All UPS systems switch to normal mode.
5. If the display of one of the UPS systems displays active warning/
error messages, rectify these problems before you proceed with
commissioning the system (see
Troubleshooting
).
6. Check whether the UPS systems generate the same output
voltage. The output voltages may deviate by a maximum of
0.5 V. Otherwise, make the appropriate setting (see
Settings
menu
).
7. Switch on the output switches of the UPS systems and then
switch on the main output switch. The UPS systems are now
working in redundant/parallel mode.
8. Switch the load on and check whether the connected load is
supplied.
Содержание 10000 3/1 XANTO S Series
Страница 2: ...2 192 XS10000 XS20000_31_manual_ger_eng_it_V1 1 2 doc R Kistler ...
Страница 64: ...64 192 XS10000 XS20000_31_manual_ger_eng_it_V1 1 2 doc R Kistler ...
Страница 66: ...66 192 XS10000 XS20000_31_manual_ger_eng_it_V1 1 2 doc R Kistler ...
Страница 126: ...T E C H N I C A L D A T A 126 192 XS10000 XS20000_31_manual_ger_eng_it_V1 1 2 doc R Kistler 9 3 CE conformity ...
Страница 128: ...128 192 XS10000 XS20000_31_manual_ger_eng_it_V1 1 2 doc R Kistler ...
Страница 130: ...130 192 XS10000 XS20000_31_manual_ger_eng_it_V1 1 2 doc R Kistler ...
Страница 190: ...D A T I T E C N I C I 190 192 XS10000 XS20000_31_manual_ger_eng_it_V1 1 2 doc R Kistler 9 3 Dichiarazione CE ...
Страница 192: ...192 192 XS10000 XS20000_31_manual_ger_eng_it_V1 1 2 doc R Kistler ...