DIP switches and straps of the Crocus CNV
Crocus CNV
32
User manual
3.1.2 DIP switches of the Table Top
DIP switch bank DS5
The following table gives an overview of DIP switch bank DS5 of the TT:
DIP switch name
DS5 no.
Setting
Function
on
Start up from flash memory.
start-up mode
1
off
Start up in boot mode.
on
Normal operation.
load default
configuration
2
off
Load default configuration.
on
Inverted X21 Tx clock polarity.
X21 Tx clock
polarity inversion
3
off
Normal X21 Tx clock polarity.
-
4
-
- Factory setting. Do not change! -
DIP switch bank DS3
The following table gives an overview of the DIP switches on DIP switch bank DS3:
DIP switch name
DS3 no.
Setting
Function
on
The receive B signal (RxB) of the
onboard G703 interface is
connected
to the earth.
1
off
The receive B signal (RxB) of the
onboard G703 interface is
disconnected
from the earth.
on
The transmit B signal (TxB) of the
onboard G703 interface is
connected
to the earth.
signal B – earth
(PGND) connection
2
(1)
off
The transmit B signal (TxB) of the
onboard G703 interface is
disconnected
from the earth.
(1)
DS3 switch 2 only has effect on the RJ45 connector. For the BNC connectors, the transmit B signal is
always
connected to the earth.
Содержание Crocus CNV
Страница 1: ...Crocus CNV Crocus CNV USER and REFERENCE MANUAL Version 1 5 500866...
Страница 10: ......
Страница 11: ...Crocus CNV User manual 1 User manual...
Страница 12: ...Crocus CNV 2 User manual...
Страница 84: ...Crocus CNV 74 Reference manual Reference manual...
Страница 85: ...Crocus CNV Reference manual 75...
Страница 136: ...Alarm attributes Crocus CNV 126 Reference manual...
Страница 165: ...Crocus CNV Annexes 155 Annexes...
Страница 166: ...Crocus CNV 156 Annexes...
Страница 168: ...Annex A product information Crocus CNV 158 Annexes...