Configuration attributes
Crocus CNV
90
Reference manual
6.4.1 General interface configuration attributes
crocusIfConv<2m/Nx64><Tt/Cv>/<dteInterface>/alarmMask
The
alarmMask
attribute enables or disables for each alarm of the corresponding object, whether it is
communicated to the central management system (e.g. HP OpenView
®
) or not.
For more information on …
•
alarms in general, refer to Section
9.2 Introducing the alarm attributes.
•
the alarms of the
<dteInterface>
object, refer to Section
9.5 - Interface alarms
.
Note that the underlying alarms may differ for each interface.
crocusIfConv<2m/Nx64><Tt/Cv>/<dteInterface>/alarmLevel
With this attribute, a priority level can be assigned to each alarm of the corresponding object. The alarm
level ranges from 0 up to 254, where 0 is the lowest and 254 is the highest priority level.
crocusIfConv<2m/Nx64>Cv/<dteInterface>/alarmContactHighMask
This attribute is only present on the CV.
The
alarmContactHighMask
attribute enables or disables for each alarm of the corresponding object,
whether:
•
a visual indication is generated (blinking error LED)
•
the alarm contacts on the CN4 card nest are driven.
crocusIfConv<2m/Nx64>Cv/<dteInterface>/alarmContactLowMask
This attribute is only present on the CV.
The
alarmContactLowMask
attribute enables or disables for each alarm of the corresponding object, whether:
•
a visual indication is generated (blinking error LED)
•
the alarm contacts on the CN4 card nest are driven.
crocusIfConv<2m/Nx64><Tt/Cv>/<dteInterface>/txClk
default:
<interface dependent>
Use this attribute to select the clocking mode of the DTE interface its transmit clock. For more information
on clocking, refer to Section
5.3 - Configuring the clocking mode
.
crocusIfConv<2m/Nx64><Tt/Cv>/<dteInterface>/rxClk
default:
fromLine
Use this attribute to select the clocking mode of the DTE interface its receive clock. For more information
on clocking, refer to Section
5.3 - Configuring the clocking mode
.
•
crocusIfConv<2m/Nx64>Tt/ remoteAlarmMask
This attribute is only present on the TT.
The
remoteAlarmMask
attribute enables or disables for each alarm of the corresponding object, whether:
•
a visual indication is generated (blinking error LED).
•
an alarm is sent to the remote Crocus CNV.
By default, all the alarms in the
remoteAlarmMask
are set to
disabled
.
Содержание Crocus CNV
Страница 1: ...Crocus CNV Crocus CNV USER and REFERENCE MANUAL Version 1 5 500866...
Страница 10: ......
Страница 11: ...Crocus CNV User manual 1 User manual...
Страница 12: ...Crocus CNV 2 User manual...
Страница 84: ...Crocus CNV 74 Reference manual Reference manual...
Страница 85: ...Crocus CNV Reference manual 75...
Страница 136: ...Alarm attributes Crocus CNV 126 Reference manual...
Страница 165: ...Crocus CNV Annexes 155 Annexes...
Страница 166: ...Crocus CNV 156 Annexes...
Страница 168: ...Annex A product information Crocus CNV 158 Annexes...