Crocus CNV
Alarm attributes
Reference manual
125
9.2.1 Configuration alarm attributes
The following four configuration alarm attributes are already explained in Chapter
6 - Configuration
attributes
, but are explained more thoroughly below.
crocusIfConv<2m/Nx64><Tt/Cv>/…/alarmMask
The
alarmMask
attribute enables or disables for each alarm of the corresponding object, whether it is
communicated to the central management system (e.g. HP OpenView
®
) or not.
Alarms are always seen in the
alarmInfo
of an object, regardless of the masking of the alarm. I.e. even if an
alarm is set to
disabled
in the
alarmMask
of an object, if the alarm condition is fulfilled then the alarm will be
set to
on
in the
alarmInfo
of that object. Also the alarm count and time in the performance information will
increment.
However, because this alarm is disabled:
•
it will not be sent to the central management system (e.g. HP OpenView
®
)
•
it will not cause a change of colour in the subsystem picture (refer to Chapter
10 - TMA subsystem
picture of the Crocus CNV
)
•
the bit string
currentAlarms
will not be shifted towards the value
previousAlarms
of the
alarmInfo
attribute
(refer to Section
9.2.2 General alarm attributes
)
crocusIfConv<2m/Nx64><Tt/Cv>/…/alarmLevel
With this attribute, a priority level can be assigned to each alarm of the corresponding object. The alarm
level ranges from 0 to 254, where 0 is the lowest and 254 is the highest priority level.
The
alarmLevel
of an unmasked, active alarm is sent to the
totalAlarmLevel
of the top object
crocusIfConv<2m/Nx64><Tt/Cv>
.
crocusIfConv<2m/Nx64>Cv/…/alarmContactHighMask
This attribute is present on the CV only.
The
alarmContactHighMask
attribute enables or disables for each alarm of the corresponding object,
whether:
•
a visual indication is generated (blinking error LED)
•
the alarm contacts on the CN4 card nest are driven
•
an alarm is sent to the remote Crocus CNV (only on the Crocus Nx64 CNV in framed mode).
crocusIfConv<2m/Nx64>Cv/…/alarmContactLowMask
This attribute is present on the CV only.
The
alarmContactLowMask
attribute enables or disables for each alarm of the corresponding object, whether:
•
a visual indication is generated (blinking error LED)
•
the alarm contacts on the CN4 card nest are driven
an alarm is sent to the remote Crocus CNV (only on the Crocus Nx64 CNV in framed mode).
crocusIfConv<2m/Nx64>Tt/…/remoteAlarmMask
This attribute is present on the TT only.
The
remoteAlarmMask
attribute enables or disables for each alarm of the corresponding object, whether:
•
a visual indication is generated (blinking error LED).
•
an alarm is sent to the remote Crocus CNV.
By default, all the alarms in the
remoteAlarmMask
are set to
disabled
.
Содержание Crocus CNV
Страница 1: ...Crocus CNV Crocus CNV USER and REFERENCE MANUAL Version 1 5 500866...
Страница 10: ......
Страница 11: ...Crocus CNV User manual 1 User manual...
Страница 12: ...Crocus CNV 2 User manual...
Страница 84: ...Crocus CNV 74 Reference manual Reference manual...
Страница 85: ...Crocus CNV Reference manual 75...
Страница 136: ...Alarm attributes Crocus CNV 126 Reference manual...
Страница 165: ...Crocus CNV Annexes 155 Annexes...
Страница 166: ...Crocus CNV 156 Annexes...
Страница 168: ...Annex A product information Crocus CNV 158 Annexes...